Cross-correlation-based transverse flow measurements using optical resolution photoacoustic microscopy with a digital micromirror device.
نویسندگان
چکیده
A cross-correlation-based method is proposed to quantitatively measure transverse flow velocity using optical resolution photoacoustic (PA) microscopy enhanced with a digital micromirror device (DMD). The DMD is used to alternately deliver two spatially separated laser beams to the target. Through cross-correlation between the slow-time PA profiles measured from the two beams, the speed and direction of transverse flow are simultaneously derived from the magnitude and sign of the time shift, respectively. Transverse flows in the range of 0.50 to 6.84 mm/s are accurately measured using an aqueous suspension of 10-μm-diameter microspheres, and the root-mean-squared measurement accuracy is quantified to be 0.22 mm/s. The flow measurements are independent of the particle size for flows in the velocity range of 0.55 to 6.49 mm/s, which was demonstrated experimentally using three different sizes of microspheres (diameters: 3, 6, and 10 μm). The measured flow velocity follows an expected parabolic distribution along the depth direction perpendicular to the flow. Both maximum and minimum measurable velocities are investigated for varied distances between the two beams and varied total time for one measurement. This technique shows an accuracy of 0.35 mm/s at 0.3-mm depth in scattering chicken breast, making it promising for measuring flow in biological tissue.
منابع مشابه
Random-access optical-resolution photoacoustic microscopy using a digital micromirror device.
We developed random-access optical-resolution photoacoustic microscopy using a digital micromirror device. This system can rapidly scan arbitrarily shaped regions of interest within a 40 μm×40 μm imaging area with a lateral resolution of 3.6 μm. To identify a region of interest, a global structural image is first acquired, then the selected region is scanned. The random-access ability was demon...
متن کاملSpatially Fourier-encoded photoacoustic microscopy using a digital micromirror device.
We have developed spatially Fourier-encoded photoacoustic (PA) microscopy using a digital micromirror device. The spatial intensity distribution of laser pulses is Fourier-encoded, and a series of such encoded PA measurements allows one to decode the spatial distribution of optical absorption. The throughput and Fellgett advantages were demonstrated by imaging a chromium target. By using 63 spa...
متن کاملCalibration-free in vivo transverse blood flowmetry based on cross correlation of slow time profiles from photoacoustic microscopy.
We propose a cross-correlation-based method to measure blood-flow velocity by using photoacoustic microscopy. Unlike in previous autocorrelation-based methods, the measured flow velocity here is independent of particle size. Thus an absolute flow velocity can be obtained without calibration. We first measured the flow velocity ex vivo, using defibrinated bovine blood. Then flow velocities in ve...
متن کاملAcoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation
Blood flow measurements have been demonstrated using the acoustic resolution mode of photoacoustic sensing. This is unlike previous flowmetry methods using the optical resolution mode, which limits the maximum penetration depth to approximately 1mm. Here we describe a pulsed time correlation photoacoustic Doppler technique that is inherently flexible, lending itself to both resolution modes. Do...
متن کاملNontranslational three-dimensional profilometry by chromatic confocal microscopy with dynamically configurable micromirror scanning.
A confocal microscope profilometer, which incorporates chromatic depth scanning with a diffractive optical element and a digital micromirror device for configurable transverse scanning, provides three-dimensional (3D) quantitative measurements without mechanical translation of either the sample or the microscope. We used a microscope with various objective lenses (e.g., 40x, 60x, and 100x) to a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical optics
دوره 18 9 شماره
صفحات -
تاریخ انتشار 2013