Stable Atrial Sensing on Long-Term Follow Up of VDD Pacemakers

نویسندگان

  • Ashok Shah
  • Jairam Aithal
  • Dhiraj Narula
  • Prafulla Kerkar
چکیده

BACKGROUND The hemodynamic advantages of maintaining AV synchrony through AV synchronous pacing are widely known as compared to single chamber pacing. DDD pacemaker implantation entails higher cost and is technically more challenging than the VDD pacemaker. METHODS Seventy one patients underwent VDD lead (Biotronik GmbH, St. Jude Medical and Medtronic Inc.) implantation at KEM hospital, Mumbai during a period of 3 years through subclavian, axillary and cephalic routes for degenerative, post-surgical or congenital high grade atrioventricular or complete heart block. They were followed up regularly for ventricular threshold and P wave amplitude of the floating atrial dipole. RESULTS Follow up data of almost 95% of patients is available for a period of 15.8 +/- 6.7 months. P wave amplitude at implant was 2.1 +/- 0.7mV and at follow up 1.1 +/- 0.6mV with mean ventricular threshold of <0.5V at implant and <1V at follow-up. CONCLUSION Implantation of a single lead VDD pacemaker is possible in all patients with symptomatic AV block and intact sinus node function without any technical complications. P wave sensing is reliable and consistent with floating atrial lead at an average follow up of 15.8 months, providing an excellent alternative to DDD pacemaker implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective analysis of mode survival, reliability of atrial sensing and incidence of atrial tachyarrhythmias in 307 single-lead VDD pacemaker patients.

AIMS The aim of this retrospective analysis was to investigate VDD mode survival, development of atrial tachyarrhythmias (AT), and long-term atrial sensing performance of VDD pacing systems. METHODS AND RESULTS We implanted single-lead VDD pacemakers in patients with isolated atrioventricular block and performed a retrospective analysis of 307 patients who had their devices implanted between ...

متن کامل

Immediate and mid-term safety and efficacy of single lead VDD pacemakers for patients with atrioventricular block and normal sinus node function--a single centre experience.

INTRODUCTION Single lead atrial synchronous ventricular pacing (VDD) is increasingly being used in place of conventional dual chamber pacing (DDD) for patients with atrioventricular block and preserved sinus node function. Compared to the latter, VDD pacemakers provide similar haemodynamic benefits derived from atrial synchronous pacing, with the added benefit of an easier implant procedure. ...

متن کامل

Predictors of inappropriate atrial sensing in long-term VDD-pacing systems.

AIMS The efficacy and stability of the atrial electrode sensing function is essential for maintaining atrioventricular (AV) synchrony. This study aimed to explore the long-term reliability and causes of the long-term sensing failure of VDD systems. METHODS AND RESULTS We enrolled all the patients with complete or high-degree AV block who received VDD pacemakers between August 1994 to January ...

متن کامل

Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker?

BACKGROUND Dual chamber pacemakers (single chamber pacing dual chamber sensing cardiac pacemaker (VDD) and dual chamber pacing and sensing cardiac pacemaker (DDD)) are being used frequently in children and adolescents. The aim of this study was to verify the safety and performance of the VDD and DDD pacing systems, and to evaluate the differences between two pacing modes with regard to atrial s...

متن کامل

Comparative Study of Electrical Stimulation of the Heart with VDD and DDD Pacemakers as to the Evolution to Atrial Fibrillation

INTRODUCTION The pacemaker implantation VDD is considered simpler, faster, less expensive and causes fewer complications compared to DDD. However, the VDD pacemaker has not been widely used in many centers, perhaps for fear of dysfunction of the sinus node and the reduction of atrial sensitivity by the pacemaker during follow-up after implantation. OBJECTIVE To compare patients with DDD and V...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006