Comparative value of attachment measurements in implant dentistry.

نویسندگان

  • Herbert Deppe
  • Stefan Wagenpfeil
  • Karl Donath
چکیده

PURPOSE In implant dentistry, the level of bone attachment is normally assessed by clinical and radiologic parameters. In the literature, however, the accuracy of these measurements has been a source of controversy. The purpose of this study was to assess the reliability of attachment measurements in the beagle dog model. MATERIALS AND METHODS In 6 beagle dogs, a total of 60 implants were placed. Bony defects resulting from plaque accumulation were treated surgically. All defects were evaluated at the time of surgery (T3) and 4 months later (T4). Evaluation included standardized measurements on radiographs, pressure-forced implant probing, and histometry. Furthermore, both conventional and digital radiographic techniques were used. RESULTS Both radiographic techniques showed very similar results at T3 and T4. At time T4, pressure-forced probing revealed statistically significantly different values than those obtained with radiography and histometry. When radiographic and histometric measurements were compared, no significant differences were found at either time T3 or time T4. DISCUSSION In this study, histometry showed better accordance with radiography than with pressure-forced probing. These results support the hypothesis that peri-implant attachment should be evaluated with a combination of both clinical and radiologic parameters. CONCLUSION The exclusive use of radiography cannot be recommended for the measurement of peri-implant attachment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Amount of Wear in Attachment of Implant-Supported Overdentures in Mandible

Background and objectives: One of the simplest and cheapest attachments for overdentures, is the ball-type attachment, however, keeping it during the first year of prosthesis delivery and after that is one of the main concerns of dentists. The present study aimed to assess the wear of matrix in overdentures attachment supported by one, two and three implants in the mandible. Materials and metho...

متن کامل

Stress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis

Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...

متن کامل

Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures

Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...

متن کامل

Comparative analysis of 2 resonance frequency measurement devices: Osstell Mentor and Osstell ISQ.

OBJECTIVE Comparing reliability of Osstell Mentor and Osstell ISQ in implant stability measurement, and assessing whether their measurements are comparable. MATERIALS AND METHOD Implant stability was measured with both devices on 58 implants in 15 patients. Six measurements were completed with each device with 2 different transducers (3 measurements with each transducer), that is, 12 measurem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2004