Mass spectrometric analysis of small negative ions (e/m < 100) produced by DC negative corona discharge in ozonised wet air both in flow and flow-stopped regimes was conducted at pressure of 30 kPa. The point-to-plain electrode system has been used. The yield of individual ions is strongly affected by trace concentrations of ozone in both regimes. Ozone concentration greater than 25 ppm is sufficient to completely suppress the appearance of O2 and a NO2 ion as well as theirs clusters in the mass spectra. The temporal increase in concentration of NO3 ions and NO3.(H2O)n (n = 1, 2) hydrated clusters was observed in flow-stopped regime accompanied by reduction in yield of CO3 ion and its water clusters CO3 .(H2O)n (n = 1, 2), which otherwise are the dominant ions in flowing wet air free of ozone. In contrast the addition of ozone into the flow of wet air resulted in evident increase in abundance of the clusters CO3.(H2O)n (n = 1, 2). This is an evidence of an active role of nitrous oxide produced in flow-stopped regime in sufficient amount. The measured electrical conductivity of drift region confirmed the role of additional dissociative attachment of electrons by ozone molecules as well as a formation of clusters of lower mobility with increasing ozone concentration in the discharge gap.
منابع مشابه
Negative ions formed in N2/CH4/Ar discharge – A simulation of Titan’s atmosphere chemistry
The formation of negative ions produced in a negative point-to-plane corona discharge fed by a Ar/N2/CH4 gas mixture has been studied using mass spectrometry. The measurements were carried out in flowing regime at ambient temperature and a reduced pressure of 460 mbar. The CN− anion has been found to be the most dominant negative ion in the discharge and is believed to be the precursor of heavi...
متن کامل/Ar discharge – a simulation of Titan’s atmosphere chemistry
The formation of negative ions produced in a negative point-to-plane corona discharge fed by a Ar/N2/CH4 gas mixture has been studied using mass spectrometry. The measurements were carried out in flowing regime at ambient temperature and a reduced pressure of 460 mbar. The CN− anion has been found to be the most dominant negative ion in the discharge and is believed to be the precursor of heavi...
متن کاملAn Experimental Study of the Effect of High Electric Field on Mass Transfer Enhancement
Applying corona wind as a novel technique can lead to a great level of heat and mass transfer augmentation by using a very small amount of energy. The enhancement of forced flow evaporation rate by applying electric field (corona wind) has been experimentally evaluated in this study. Corona wind produced by a fine wire electrode charged with positive high DC voltage impinges on water surface an...
متن کاملDifferences etween Negative and Positive Corona Discharge Fed by CO2 in Ozone Production
The efficiency of ozone generation in DC corona discharge fed by carbon dioxide has been studied. A simple coaxial system of electrodes has been used for generation of both negative and positive corona discharge in flowing gas. The ozone concentration has been measured on the outlet of the reactor by UV absorption spectroscopy methods. Ozone generation in the negative corona discharge was found...
متن کاملInactivation of bacteria using dc corona discharge: role of ions and humidity.
Here we present the results of an experimental study of the effect of ions produced in a dc corona discharge on inactivation of bacteria on the surface of agarose gel. Both positive and negative corona discharges in various gases at different humidities were studied. The measurements in air, O(2), N(2), Ar and He mixtures show that there is no inactivation in pure N(2), pure O(2) and an N(2)-H(...