Validation of Carotid Duplex and Power M-mode Transcranial Doppler for Detection of Internal Carotid Artery Stenosis

نویسندگان

  • Kavian Ghandehari
  • Maher Saqqur
  • Ashfaq Shuaib
چکیده

Background – Carotid duplex ultrasound (CDU) is routinely used for detection of extracranial internal carotid artery (EICA) stenosis in stroke patients. Power M-mode transcranial Doppler (PMD-TCD) is a new technology designed for studying intracranial vessels. This prospective study was performed for validation of CDU versus digital subtraction cerebral angiography (DSA) and PMD-TCD versus CDU in detection of EICA stenosis. Methods – Part I: Validation of CDU versus DSA in 50 stroke patients (100 carotids) admitted to Walter Mackenzie Center, Canada in 2003. All of the CDUs were performed by a sonographer with an HP Sono 5500 device (USA) and a 13-MHz linear probe. The degree of EICA stenosis was measured using DSA according to North American symptomatic carotid endarterectomy trial (NASCET) method by another neuroradiologist blinded to CDU results. Part II: Validation of PMD-TCD versus CDU in another group of 50 patients (100 carotids) with stroke. All PMD-TCD studies were performed with a TCDM100 device (Spencer, USA) and a 2-MHz probe by a sonographer blinded to CDU results. Results – Part I: Compared with DSA, CDU had a sensitivity of 96%, specificity of 100%, positive predictive value (PPV) of 100%, and negative predictive value (NPV) of 82% in detecting EICA stenosis of 50% and over. CDU versus DSA confirmed EICA stenosis of 70% and over with a sensitivity of 88%, specificity of 95%, PPV of 96%, and NPV of 87%. Part II: Compared with CDU, PMD-TCD had a sensitivity of 45%, specificity of 94%, PPV of 50%, and NPV of 93% for detection of EICA-stenosis of 50% and over. PMD-TCD, when compared with CDU, confirmed EICA-stenosis of 70% and over with a sensitivity of 43%, specificity of 99%, PPV of 75% and NPV of 96%. Conclusion – In our center, CDU is a highly reliable noninvasive diagnostic tool for detection of EICA stenosis. PMD-TCD of carotid has a moderate sensitivity for detection of EICA stenosis and is not recommended as a screening test for this purpose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

Power M-Mode Doppler and single-gate spectral analysis using a 2-MHz pulsed-wave Doppler transducer to directly detect cervical internal carotid artery stenosis: use of the continuity principle: report of a novel technique.

BACKGROUND AND PURPOSE We hypothesized that direct cervical investigation with Power M-Mode Doppler (PMD) combined with single-gate Doppler spectral analysis (SGDSA) using a 2-MHz pulsed-wave Doppler transducer would show reasonable accuracy parameters when compared with standard color-coded carotid duplex ultrasound (CDU). METHODS We prospectively screened for cervical internal carotid arter...

متن کامل

بررسی دقت و همبستگی سونوگرافی داپلر رنگی با آنژیوگرافی در تعیین شدت تنگی عروق کاروتید گردنی در بیماران ایسکمی مغزی

This is retrospective double-blind research, which was carried out in Imam Khomeini hospital in order to study the accuracy of color Doppler ultrasonography for detecting the site and grade of stenosis in cervical carotid artery. 40 patients with mean age of 62 years studied with color Doppler before DSA angiography. The most common sites of stenosis were left internal carotid (39.5%) and right...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

بررسی تنگی عروق کاروتید داخلی در مبتلایان به حملات ایسکمی گذرا در بیمارستان امام خمینی در سال های 1375 تا 1377

This is a prospective descriptive research which was carried out in Imam Khomeini Hospital related to Tehran University during two years (1375-1377) in order to study the incidence of internal carotid stenosis in patients who suffered from TIA ot minor stroke. It was evaluated by duplex sonography. Risk factors of carotid stenosis were studied. 1052 patients who had cerebrovascular accident adm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004