A simple method for validation and verification of pipettes mounted on automated liquid handlers.
نویسندگان
چکیده
We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadruplicates in a flat-bottom 96-well microtiter plate, manually using calibrated pipettes. Each pipette of the liquid handler (1-8) dispensed a selected volume (1-200 μL) of OrangeG eight times into the wells of the microtiter plate. All wells contained a total of 200 μL liquid. The absorbance was read, and the dispensed volume of each pipette was calculated based on a plot of volume and absorbance of a known set of OrangeG dilutions. Finally, the percent inaccuracy (%d) and the imprecision (%CV) of each pipette were calculated. Using predefined acceptance criteria, each pipette was then either approved or failed. Failed pipettes were either repaired or the volume deviation was compensated for by applying a calibration curve in the liquid-handler software. We have implemented the procedure on a Sias Xantus, an MWGt TheONYX, four Tecan Freedom EVO, a Biomek NX Span-8, and four Biomek 3000 robots, and the methods are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates.
منابع مشابه
Ratiometric Photometry Improves Laboratory Quality Assurance New Methodology Accurately and Precisely Verifies Low-Volume Liquid Delivery
LEVEL: BASIC Laboratory scientists often assume that their liquidhandling instruments, from pipettes to automated liquid handlers, are operating within specification. But given that data integrity for applications from drug discovery to molecular diagnostics relies on accurate and precise liquid delivery, that can be a very risky assumption with high costs of failure. Those costs and risks are ...
متن کاملAutomatic measurement of instantaneous changes in the walls of carotid artery with sequential ultrasound images
Introduction: This study presents a computerized analyzing method for detection of instantaneous changes of far and near walls of the common carotid artery in sequential ultrasound images by applying the maximum gradient algorithm. Maximum gradient was modified and some characteristics were added from the dynamic programming algorithm for our applications. Methods: The algorithm was evaluat...
متن کاملVerification and Validation of Common Derivative Terms Approximation in Meshfree Numerical Scheme
In order to improve the approximation of spatial derivatives without meshes, a set of meshfree numerical schemes for derivative terms is developed, which is compatible with the coordinates of Cartesian, cylindrical, and spherical. Based on the comparisons between numerical and theoretical solutions, errors and convergences are assessed by a posteriori method, which shows that the approximations...
متن کاملFace Detection with methods based on color by using Artificial Neural Network
The face Detection methodsis used in order to provide security. The mentioned methods problems are that it cannot be categorized because of the great differences and varieties in the face of individuals. In this paper, face Detection methods has been presented for overcoming upon these problems based on skin color datum. The researcher gathered a face database of 30 individuals consisting of ov...
متن کاملOptimization of a Dispersive Liquid-Liquid Microextration Method for Analysis of Chlorpyrifos in Urine Using the Chemometrics Method
Aims: The use of simple, low cost, high -efficiency extraction methods for sample preparation in the forensic toxicology has been considered. Nowadays, the chemometrics technique can be used to determine the influencing factors on the response to optimize extraction methods. The aim of this study was to design and optimize a dispersive liquid-liquid microextraction (DLLME) method for extraction...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of laboratory automation
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2011