Electrochemical Detection of Single Phospholipid Vesicle Collisions at a Pt Ultramicroelectrode.
نویسندگان
چکیده
We report the collision behavior of single unilamellar vesicles, composed of a bilayer lipid membrane (BLM), on a platinum (Pt) ultramicroelectrode (UME) by two electrochemical detection methods. In the first method, the blocking of a solution redox reaction, induced by the single vesicle adsorption on the Pt UME, can be observed in the amperometric i-t response as current steps during the electrochemical oxidation of ferrocyanide. In the second technique, the ferrocyanide redox probe is directly encapsulated inside vesicles and can be oxidized during the vesicle collision on the UME if the potential is poised positive enough for ferrocyanide oxidation to occur. In the amperometric i-t response for the latter experiment, a current spike is observed. Here, we report the vesicle blocking (VB) method as a relevant technique for determining the vesicle solution concentration from the collisional frequency and also for observing the vesicle adhesion on the Pt surface. In addition, vesicle reactor (VR) experiments show clear evidence that the lipid bilayer membrane does not collapse or break open at the Pt UME during the vesicle collision. Because the bilayer is too thick for electron tunneling to occur readily, an appropriate concentration of a surfactant, such as Triton X-100 (TX100), was added in the VR solution to induce loosening of the bilayer (transfection conditions), allowing the electrode to oxidize the contents of the vesicle. With this technique, the TX100 effect on the vesicle lipid bilayer permeability can be evaluated through the current spike charge and frequency corresponding to redox vesicle collisions.
منابع مشابه
Analysis of diffusion-controlled stochastic events of iridium oxide single nanoparticle collisions by scanning electrochemical microscopy.
We investigated the electrochemical detection of single iridium oxide nanoparticle (IrO(x) NP) collisions at the NaBH(4)-treated Pt ultramicroelectrode (UME) in a scanning electrochemical microscope (SECM) over an insulating surface. The NP collision events were monitored by observing the electrocatalytic water oxidation reaction at potentials where it does not take place on the Pt UME. These c...
متن کاملDNA analysis by application of Pt nanoparticle electrochemical amplification with single label response.
This study demonstrates a highly sensitive sensing scheme for the detection of low concentrations of DNA, in principle down to the single biomolecule level. The previously developed technique of electrochemical current amplification for detection of single nanoparticle (NP) collisions at an ultramicroelectrode (UME) has been employed to determine DNA. The Pt NP/Au UME/hydrazine oxidation reacti...
متن کاملResistive Pulse Delivery of Single Nanoparticles to Electrochemical Interfaces.
An experimental system for controlling and interrogating the collisions of individual nanoparticles at electrode/electrolyte interfaces is described. A nanopipet positioned over a 400 nm radius Pt ultramicroelectrode is used to deliver individual nanoparticles, via pressure-driven solution flow, to the underlying electrode, where the nanoparticles undergo collisions and are detected electrochem...
متن کاملTunneling ultramicroelectrode: nanoelectrodes and nanoparticle collisions.
We describe the fabrication of a nanometer-size electrode based on an insulating TiO2 film and a metal nanoparticle (NP). The TiO2 film is deposited on the conducting Pt surface of an ultramicroelectrode (UME) to block electron transfer (ET) to solution species. The film thickness is, however, thin enough to enable tunneling to Pt NPs; thus, the subsequent contact of metal NP to the TiO2 film r...
متن کاملObserving iridium oxide (IrO(x)) single nanoparticle collisions at ultramicroelectrodes.
We describe the electrochemical detection of single iridium oxide nanoparticle (IrO(x) NP) collisions on a NaBH(4)-treated Pt ultramicroelectrode (UME). We observe single NP events through the enhanced current by electrocatalytic water oxidation, when IrO(x) contacts the electrode and transiently sticks to it. The overall current transient consists of repeated current spikes that return to the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Langmuir : the ACS journal of surfaces and colloids
دوره 31 42 شماره
صفحات -
تاریخ انتشار 2015