Exergy Analysis of an Absorption Refrigeration System Using an Iconic Liquid as a Working Fluid in the Chemical Compressor

نویسندگان

  • Yoon Jo Kim
  • Sarah Kim
  • Yogendra K. Joshi
  • Andrei G. Fedorov
  • Paul A. Kohl
  • Yoon Jo KIM
  • Sarah KIM
چکیده

The first and second law of thermodynamics are applied to an ionic-liquid (IL) based absorption refrigeration system for high power electronics cooling. The IL is a salt in a liquid state usually with an organic cation and inorganic anion. It provides an alternative to the normally toxic working fluids used in the chemical compression loop, such as ammonia in conventional absorption systems. The use of ILs also eliminates crystallization and metal-compatibility problems of the water/LiBr system. In this study, mixtures of refrigerants and imidazolium-based ILs are theoretically explored as the working fluid pairs in a miniature absorption refrigeration system, so as to utilize waste-heat to power a refrigeration/heat pump system for electronics cooling. A mathematical model based on exergy analysis is employed to characterize the performance for specific refrigerant/IL pairs. Both the coefficient of performance (COP) and the exergetic coefficient of performance (ECOP) of the absorption system and components are evaluated. The thermodynamic properties of ILs are evaluated using the correlations based on group contribution methods. A non-random two-liquid (NRTL) model is built and used to predict the solubility of the mixtures. The properties of the refrigerants are determined using REFPROP 6.0 software. Saturation temperatures at the evaporator and condenser are set at 25 o C and 50 o C, respectively. The power dissipation at the evaporator is fixed at 100 W with the operating temperature set at 85 o C, which are the benchmark conditions for high performance microprocessor chip cooling. The desorber and absorber outlet temperatures are adjusted to evaluate the system performance variation with respect to the operating condition change. The effect of the refrigerant/IL compatibility, alkyl chain length of the IL cation, and thermodynamic properties of the refrigerants, such as latent heat of evaporation, on the ECOP is investigated. Also the exergy destruction of each component of the cycle is evaluated and discussed as a means to identify the critical component(s) of the system that would require optimization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exergoeconomic Evaluation of an Integrated Nitrogen Rejection Unit with LNG and NGL Co-Production Processes Based on the MFC and Absorbtion Refrigeration Systems

Natural gas is often associated with nitrogen and heavy compounds. The Heavy components in the natural gas not only can feed downstream units, owing to the low temperature process may be formed solid as well. Therefore, heavy components separation can be a necessity and produce useful products. Virtually, all natural gases are containing nitrogen ​​that would lower the heating value of natural ...

متن کامل

Advanced Exergy Evaluation of an Integrated Separation Process with Optimized Refrigeration System

Advanced exergy analysis is a tool to split the exergy destruction of the system to achieve a better perspective about the potentials of a system for improvements. In addition, the component interactions and their exergy destruction dependency with the other equipment are investigated through the advanced exergy analysis. For this purpose, it divides the exergy destruction calculated by convent...

متن کامل

Exergy Analysis of a Novel Combined System Consisting of a Gas Turbine, an Organic Rankine Cycle and an Absorption Chiller to Produce Power, Heat and Cold

The current work investigates the exergy analysis of a new system to generate power, heat, and refrigeration. In the proposed system, the heat loss of a gas turbine (GT) is first recovered by a Heat Recovery Steam Generator (HRSD), then by an Organic Rankine Cycle (ORC) to generate warm water and additional power, respectively. In the ORC, reheating is used to increase the output power, the req...

متن کامل

Advanced Exergoeconomic Analysis of C3MR, MFC and DMR ‎Refrigeration Cycles in an Integrated Cryogenic Process

C3MR, MFC, and DMR processes in an integrated LNG-NGL-NRU structure are investigated using the conventional and advanced exergy and exergoeconomic analyses. The results of advanced exergy analysis reveal that in most of the equipment, the highest amount of irreversibility is occurred because of endogenous exergy destruction. In C3MR process, compressor C5 with 9730 kW; in MFC process, compresso...

متن کامل

Saving Energy by Exergetic Analysis of MTP Process Refrigeration System

The exergetic analysis is a tool that has been used successfully in many studies aiming a more rational energy consumption to reduce the cost of processes. With this analysis, it is possible to perform an evaluation of the overall process, locating and quantifying the degradation of exergy. This paper applies exergy approach for analyzing the heat exchanger network design and refrigeration of M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014