A novel amplification strategy for genotyping with liquid chromatography-electrospray ionization mass spectrometry.
نویسندگان
چکیده
Among numerous available genotyping techniques, mass spectrometry (MS) based methods play a major role in providing high quality genotype data at reasonable costs for research and diagnostics, e.g. for pharmacogenetic applications. Ion-pair reversed-phase liquid chromatography hyphenated to electrospray ionization time-of-flight MS (ICEMS) is, for example, a powerful instrument that allows a direct characterization of complex mixtures of polymerase chain reaction (PCR) amplified DNA fragments. Current limitations of PCR-ICEMS genotyping are mainly concerned with the multiplex PCR set-up. Assay development often requires time-consuming primer design and intensive optimization of PCR conditions. To overcome this restraint, a robust amplification strategy originally combined with arrayed primer extension genotyping was transferred and adapted to ICEMS genotyping. The modifications involved limitation of the primer length, application of two universal sequences and amplification with an appropriate DNA polymerase. To demonstrate the applicability of the novel amplification strategy for ICEMS, a 23-plex pharmacogenetic genotyping assay was developed. After slight optimization steps, an efficient and quantitatively balanced amplification of all targeted markers was achieved, resulting in a convenient characterization of the multiplexed PCR fragments with ICEMS. Expenditure of time, costs and hands-on work associated with assay design and optimization was dramatically lowered compared to previous multiplex PCR-ICEMS assays. The developed 23-plex assay was applied in a pharmacogenetic study including 284 individuals (genotype call rate 99.0%). A total of 399 SNPs were retyped by Sanger sequencing (concordance rate 99.8%). The PCR-ICEMS assay turned out to be an accurate, reliable, cost-effective and a ready-to-use tool for pharmacogenetic genotyping.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملRelative Determination Approach to the Metabolites of Protoberberine Alkaloids in Rat Urine by Liquid Chromatography Tandem Mass Spectrometry for the Comparative Studies on Rhizome coptidis and Zuojinwan Preparation
The lack of authentic standards has limited the quantitative analysis of herbal drugs in biological samples. The present work demonstrated a practicable strategy for the assay of herbs and their metabolites independent of authentic standards. A liquid chromatography–electrospray ionization–mass spectrometry (LC–ESI–MS) method for the qualitative and quantitative determination of the metabolites...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 137 22 شماره
صفحات -
تاریخ انتشار 2012