AC electrothermal enhancement of heterogeneous assays in microfluidics.

نویسندگان

  • Hope C Feldman
  • Marin Sigurdson
  • Carl D Meinhart
چکیده

AC-driven electrothermal flow is used to enhance the temporal performance of heterogeneous immuno-sensors in microfluidic systems by nearly an order of magnitude. AC electrokinetic forces are used to generate electrothermal flow, which in turn produces a circular stirring fluid motion that enhances the transport of diffusion-limited proteins. This provides more binding opportunities between suspended antigens and wall-immobilized antibodies. We investigate experimentally the effectiveness of electrothermal stirring, using a biotin-streptavidin heterogeneous assay, in which biotin is immobilized, and fluorescently-labeled streptavidin is suspended in a high conductivity buffer (sigma = 1.0 S m(-1)). Microfabricated electrodes were integrated within a microwell and driven at a frequency of f= 200 kHz and 10 V(rms). Fluorescent intensity measurements show that for a five minute assay, electrothermal stirring increases the binding rate by a factor of almost nine. Similar binding improvement was measured for longer assays, up to fifteen minutes. The electrothermal enhancement of this assay was modeled numerically and agrees with experimental binding rates. The measured fluid velocity of 22 +/- 2 microm s(-1) was significantly lower than that predicted by the numerical model, 1.1 mm s(-1), but nevertheless shows the same fourth power dependence on applied potential. The results demonstrate the ability for electrothermal stirring to reliably improve the response time and sensitivity within a given time limit for microfluidic diffusion-limited sensors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrothermal stirring for heterogeneous immunoassays.

A technique is proposed to enhance microfluidic immuno-sensors, for example, immunoassays, in which a ligand immobilized on a microchannel wall specifically binds analyte flowing through the channel. These sensors can be limited in both response time and sensitivity by the diffusion of analyte to the sensing surface. In certain applications, the sensitivity and response of these heterogeneous i...

متن کامل

Long-range electrothermal fluid motion in microfluidic systems.

AC electrothermal flow (ACEF) is the fluid motion created as a result of Joule heating induced temperature gradients. ACEF is capable of performing major microfluidic operations, such as pumping, mixing, concentration, separation and assay enhancement, and is effective in biological samples with a wide range of electrical conductivity. Here, we report long-range fluid motion induced by ACEF, wh...

متن کامل

AC electrothermal manipulation of conductive fluids and particles for lab-chip applications.

AC electrokinetics has shown great potential for microfluidic functions such as pumping, mixing and concentrating particles. So far, electrokinetics are typically applied on fluids that are not too conductive (<0.02 S/m), which excludes most biofluidic applications. To solve this problem, this paper seeks to apply AC electrothermal (ACET) effect to manipulate conductive fluids and particles wit...

متن کامل

Interactions of electrical fields with fluids: laboratory-on-a-chip applications.

The area of 'laboratory-on-a-chip', miniaturised or microfluidic analysis systems, is a rapidly developing field. At the microscale, electrokinetic processes become enhanced, and the advent of AC electrokinetics (EK) in recent years further promotes the development of electrokinetic devices for microfluidics. ACEK has demonstrated to manipulate fluids and polarisable particles at low voltages w...

متن کامل

DC-biased AC-electrokinetics: a conductivity gradient driven fluid flow.

This paper studies the principles of fluid flow manipulation based on DC-biased AC-electrokinetics. This method makes use of planar parallel electrodes in a microfluidic channel in contact with an electrolyte solution, with a DC biased AC electrical signal applied to the electrode pair. Due to the application of DC bias, incipient Faradaic electrolytic reactions take place resulting in an incre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 7 11  شماره 

صفحات  -

تاریخ انتشار 2007