Development of an Ultrasonic Airflow Measurement Device for Ducted Air
نویسندگان
چکیده
In this study, an in-duct ultrasonic airflow measurement device has been designed, developed and tested. The airflow measurement results for a small range of airflow velocities and temperatures show that the accuracy was better than 3.5% root mean square (RMS) when it was tested within a round or square duct compared to the in-line Venturi tube airflow meter used for reference. This proof of concept device has provided evidence that with further development it could be a low-cost alternative to pressure differential devices such as the orifice plate airflow meter for monitoring energy efficiency performance and reliability of ventilation systems. The design uses a number of techniques and design choices to provide solutions to lower the implementation cost of the device compared to traditional airflow meters. The design choices that were found to work well are the single sided transducer arrangement for a "V" shaped reflective path and the use of square wave transmitter pulses ending with the necessary 180° phase changed pulse train to suppress transducer ringing. The device is also designed so that it does not have to rely on high-speed analogue to digital converters (ADC) and intensive digital signal processing, so could be implemented using voltage comparators and low-cost microcontrollers.
منابع مشابه
Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملEffects of obstructions, sample size and sample rate on ultrasonic anemometer measurements underground
In fluctuating airflow, continuous air velocity recording is the most reliable method of air velocity measurement. It allows for fast recognition of changes and the calculation of long-term averages. Also, it enables the mine operator to identify when the airflow has decreased to a point requiring action. Using ultrasonic anemometers provides an accurate option for continuous air velocity monit...
متن کاملDeveloping and Validating a New Wireless Wearable Device for Balance Measurement in Sport and Clinical Setting
One of the new clinical techniques to assess the lower body parameters is the wearable ultrasonic sensors. The device which can measure the static and dynamic balance abilities in sport and clinical setting by the traveled signals of ultrasonic transmitter and receiver between two feet was developed and validated. The new device consisted of a pressure gauge and a digital centimeter indicator a...
متن کاملNatural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations
The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...
متن کاملMethodology for airflow rate measurements in a naturally ventilated mock-up animal building with side and ridge vents
11 Currently there exists no generally accepted reference technique to measure the ventilation rate 12 through naturally ventilated (NV) vents. This has an impact on the reliability of airflow rate control 13 techniques and emission rate measurements in NV animal houses. As an attempt to address this issue a 14 NV test facility was built to develop new airflow rate measurement techniques for bo...
متن کامل