Comparison of bronchial responsiveness to ultrasonically nebulized distilled water (UNDW), methacholine, and ultrasonically nebulized distilled cold water (UDCW) in patients with sulfur mustard gas-induced asthma

نویسندگان

  • Ali Emad
  • Yasaman Emad
چکیده

OBJECTIVE To evaluate bronchial challenges using three different stimuli as screening tools for bronchial hyper-responsiveness in sulfur mustard gas-induced asthma. DESIGN Randomized, cross-over clinical study. SETTING University hospital. PATIENTS Eighteen veterans with mustard gas-induced asthma and 18 normal veterans as the control group. INTERVENTION Pulmonary function tests and inhalation challenges with ultrasonically nebulized distilled water (UNDW), methacholine, and ultrasonically nebulized cold water (UNDCW) were performed on all patients and subjects. RESULTS Six mustard gas-induced asthmatic veterans did not respond to a 20% in FEV(1) after distilled water (13.3%), and two of them (11.11%) did not respond with distilled cold water; all responded with methacholine. Only one healthy subject developed a PC20 FEV(1) after methacholine but did not with both distilled water and distilled cold water challenges. The asthmatic patients were sensitive to distilled water with a median PD20 of 7.24 +/- 3.83 ml (range 2.54 ml to 15.83 ml), and sensitive to cold water with a median PD20 of 6.42 +/- 6.24 ml (range 1.92 ml to 25.15 ml). The median PC20 methacholine was 1.90 +/- 1.88 mg/ml (range 0.14 mg/ml to 6.20 mg/ml). In patients with a positive response to the distilled water challenge test, no significant correlation was found between PC20 of methacholine and PD20 of distilled water (Rho = -0.34, p = 0.25), whereas in patients whose responses to distilled cold water (DCW) were positive, PD20 of distilled cold water (DCW) correlated well with PC20 of methacholine (Rho = -0.69, p = 0.006). CONCLUSION Overall, the methacholine challenge test is the best method to distinguish these asthmatic patients from normal subjects in this study. When compared to the methacholine challenge, although the airway response to ultrasonically nebulized distilled cold water test was somewhat less sensitive, it may be used as a simple, fast, inexpensive, and relatively reliable method to predict the absence of asthma in sulfur mustard gas-induced asthma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A guinea-pig model of ultrasonically nebulized distilled water-induced bronchoconstriction.

Ultrasonically nebulized distilled water-induced bronchoconstriction (UNDW-IB) is specific to asthma. The mechanisms underlying UNDW-IB are not fully understood, and no reproducible animal model has been reported. The purpose of this study was to develop a guinea-pig model of UNDW-IB. Ultrasonically nebulized distilled water (UNDW) was inhaled 20 min after an aerosolized antigen challenge in pa...

متن کامل

Increase in bronchial responsiveness to methacholine and late asthmatic response after the inhalation of ultrasonically nebulized distilled water.

We studied ten subjects who had an asthmatic response after the inhalation of ultrasonically nebulized distilled water and did not show any refractory period to repeated challenge with such water. The change in responsiveness to methacholine after inhalation of distilled water and the occurrence of any water-induced late asthmatic response were investigated on separate days. All of the tested s...

متن کامل

Bronchoconstrictive responses to inhaled ultrasonically nebulized distilled water and airway inflammation in asthma.

Twenty-two asthmatic patients with a range of airway hyperresponsiveness to methacholine underwent a bronchial challenge with ultrasonically nebulized distilled water (UNDW). The presence of positive responses to this stimulus was related to the extent of airway inflammation, as assessed by histochemical and immunohistochemical evaluation of bronchial biopsy specimens. Twelve patients had airfl...

متن کامل

Comparison of ultrasonically nebulized distilled water and cold-air hyperventilation challenges in asthmatic patients.

Cold-air hyperventilation (CAHC) and ultrasonically nebulized distilled water (UNDW) challenges were compared in 11 asthmatic patients who were moderately sensitive to methacholine. The challenges were performed on two separate days within one week of each other. Baseline FEV1 on each test day was greater than 70 percent of predicted. Ten of 11 subjects' FEV1 decreased at least 15 percent, and ...

متن کامل

Comparison of bronchial challenge with ultrasonic nebulized distilled water and hypertonic saline in children with mild-to-moderate asthma.

There is still controversy about the most suitable method to measure bronchial hyperresponsiveness in children. In epidemiological surveys, nonisotonic aerosols are being used increasingly for bronchial provocation testing. Our aim was to study the acceptability, safety and correlation between two published bronchial challenge tests. Two standardized protocols--the inhalation of hypertonic sali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical Toxicology (Philadelphia, Pa.)

دوره 45  شماره 

صفحات  -

تاریخ انتشار 2007