Reproducibility of Optical Coherence Tomography Retinal Nerve Fiber Layer Thickness Measurements Before and After Pupil Dilation

نویسندگان

  • Yousef Alizadeh
  • Mohammad Reza Panjtanpanah
  • Mohammad Javad Mohammadi
  • Hassan Behboudi
  • Ehsan Kazemnezhad Leili
چکیده

PURPOSE To evaluate the intra- and interobserver reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements before and after pupil dilation using spectral-domain optical coherence tomography (SD-OCT). METHODS In this observational case series, 44 eyes of 44 healthy subjects were scanned by two trained operators on the same day, using Cirrus SD-OCT (Carl Zeiss Meditec, Dublin, CA, USA). Three scans were obtained before and after pupil dilation by each operator. Mean ± standard deviation (SD) and coefficient of variation (CV) were used for description of results and variation of measurements respectively. Intraclass correlation coefficients (ICC) and Bland-Altman plots were used to evaluate validation and limits of agreement. RESULTS Overall, 23 female and 21 male subjects with mean age of 36.9±8.8 (range, 20 to 50) years were enrolled. Mean RNFL thickness before pupil dilation was 92.6±7.2 (CV, 7.8%) and 92.4±6.8 (CV, 7.4%) µm by operator one and two, respectively. After pupil dilation, mean RNFL thickness was 92.7±7.9 (CV, 8.5%) and 92.0±7.5 (CV=8.2%) µm by observer one and two, respectively. ICCs ranged from 0.900 to 0.996. Mean absolute error of the two operators was less than 4.1µm. There were no significant differences in quadrant thicknesses before and after dilation. Interestingly, mean signal strength was not significantly affected by pupil dilation. CONCLUSION In normal subjects with clear media, peripapillary RNFL thickness measurements using Cirrus SD-OCT have high inter- and intraobserver reproducibility before and after pupil dilation. Pupil dilation may not be necessary in all subjects to obtain reproducible RNFL thickness measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک

Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT  in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...

متن کامل

Clinical Applications of Optical Coherence Tomography in Ophthalmology

Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases.  Furtherm...

متن کامل

The Retinal Nerve Fiber Layer Thickness is Related to Severity of Parkinson’s Disease

Introduction: We investigated correlation between the retinal nerve fiber layer (RNFL) thickness and the severity of Parkinson's disease (PD). Methods: In this study, the RNFL thickness of 23 patients with Parkinson’s disease (PD) was compared to normal controls (NCs). PD severity was assessed by the MDS-UPDRS (movement disorder society Unified Parkinson Disea...

متن کامل

In vivo quantitative evaluation of the rat retinal nerve fiber layer with optical coherence tomography.

PURPOSE To determine whether optical coherence tomography (OCT) is useful for quantitative evaluation of the thickness of the rat retinal nerve fiber layer (RNFL) in an optic nerve crush model. METHODS An OCT system was developed with a modified commercial time-domain OCT and a superluminescent diode with a bandwidth of 150 nm. Optical components were optimized to acquire rat retinal images. ...

متن کامل

Evaluating the effect of pupil dilation on spectral-domain optical coherence tomography measurements and their quality score

BACKGROUND Spectral-domain optical coherence tomography (SD-OCT) provides fast scan speed and high scan resolution improving its diagnostic accuracy. The purpose of this study was to evaluate if SD-OCT measurements and their quality score are influenced by pupil dilation. METHODS Retinal nerve fiber layer thickness (RNFL), ganglion cell complex (GCC) and optic nerve head (ONH) were measured i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014