Microchip emitter for solid-phase extraction-gradient elution-mass spectrometry.

نویسندگان

  • Natalia Gasilova
  • Liang Qiao
  • Dmitry Momotenko
  • Mohammad Reza Pourhaghighi
  • Hubert H Girault
چکیده

A microchip electrospray emitter with a magnetic bead trap has been designed for solid-phase extraction-gradient elution-mass spectrometry (SPE-GEMS). The goal of this method is the detection of analytes at low concentrations and it is here demonstrated using reverse phase coated magnetic beads (Mbs) for the preconcentration and detection of the peptides. The sample is passed through the chip, and the peptides are retained and enriched in the trap. After washing, the peptides are released sequentially by stepwise gradient elution and electrosprayed for mass spectrometry analysis. This approach allows effective sample desalting, enrichment, sequential elution, and MS detection without the introduction of an additional separation step after SPE. Efficient preconcentration of model peptides by SPE and sequential release and analysis of peptides by GEMS were demonstrated for diluted sample solutions within the range of 1 μM to 10 nM. Fortified human blood serum, protein digest and fractions collected after protein digest OFFGEL separation were analyzed by SPE-GEMS allowing the detection of low abundance peptides usually not observed by direct mass spectrometry analysis. A mathematical model for gradient elution is proposed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Droplet Analysis with Electrospray Ionization Mass Spec- Trometry Using an Integrated Glass Microchip

ABSTRACT We describe an integrated microchip for droplet analysis with electrospray ionization mass spectrometry (ESI-MS). The chip integrated multiple modules of droplet generator, droplet extraction interface, and monolithic ESI-emitter. A novel droplet extraction interface based on a hydrophilic tongue structure was developed to transfer droplet from segmented phase to aqueous phase with hig...

متن کامل

Simultaneous determination of five minor coumarins and flavonoids in Glycyrrhiza uralensis by solid-phase extraction and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.

Minor phenolic compounds in licorice (Glycyrrhiza uralensis) have recently been proved for diverse bioactivities and favorable bioavailability, indicating that they may play an important role in the therapeutic effects or herb-drug interactions of licorice. However, so far, their abundance in licorice remains unknown. In this study, a reliable solid-phase extraction coupled with a high-performa...

متن کامل

Chemically-Modified Activated Carbon with L-Arginine for Selective Solid Phase Extraction and Preconcentration of Metal Ions

In this study, a new sorbent of chemically-modified activated carbon with L-arginine (AC-Arg) has been produced as solid-phase extraction, to trace Zn(II) and Cd(II) ions in real samples, including soil and water samples, by Flame Atomic Absorption Spectrometry (FAAS). Once the surface coverage value is determined, the surface modification has been investigated and assessed, while having em...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 85 13  شماره 

صفحات  -

تاریخ انتشار 2013