Sonographic measurement of cervical length and fetal fibronectin testing in threatened preterm labor.
نویسندگان
چکیده
OBJECTIVE In women presenting with threatened preterm labor, both fetal fibronectin and sonographic measurement of cervical length have been shown to distinguish between true and false labor. The aim of this study was to determine whether the combination of both tests provides a better prediction than the individual tests alone. METHODS We examined 195 women with singleton pregnancies presenting at 24-36 (median 31) weeks of gestation with regular and painful uterine contractions, intact membranes and cervical dilatation of less than 3 cm. On admission to the hospital fetal fibronectin positivity in cervicovaginal secretions was determined and transvaginal sonographic measurement of cervical length was carried out. The results were not made available to the attending obstetrician. The primary outcome measure was delivery within 7 days of presentation. RESULTS Delivery within 7 days occurred in 51.4% (18 of 35) of those with cervical length below 15 mm and 0.6% (1 of 160) of those with cervical length of 15 mm or more, in 21.2% (18 of 85) of the fibronectin positive group and in 0.9% (1 of 110) of the fibronectin negative group. There was a significant association between cervical length and the incidence of fibronectin positivity (r = -0.921, P = 0.003). Logistic regression analysis demonstrated that the only significant contributor to the prediction of delivery within 7 days was cervical length, with no significant contribution from fibronectin positivity, ethnic origin, maternal age, gestational age, body mass index, parity, previous history of preterm delivery, cigarette smoking, or use of tocolytics. CONCLUSIONS In women with threatened preterm labor assessment of fetal fibronectin in cervicovaginal secretions does not improve the prediction of delivery within 7 days provided by the sonographic measurement of cervical length.
منابع مشابه
Evaluation of Phosphorylated Insulin like Growth Factor Binding Protein-1 and Sonographically Measured Cervical Length for Prediction of Preterm Birth in Threatened Preterm Labor: A Clinical Approach
Background and Objectives: Measurement of cervical length using Transvaginal Sonography (TVS) is commonly used to identify those patients of threatened preterm labor who are likely to deliver. Biochemical markers in cervical secretions namely fetal fibronectin and Phosphorylated Insulin like Growth Factor Binding Protien-1 (phIGFBP-1) have also been used to improve predictability. This study ev...
متن کاملPredicting preterm birth: a cost-effectiveness analysis.
OBJECTIVE The objective of this study was to compare the cost-effectiveness of 9 strategies for the management of threatened preterm labor. STUDY DESIGN We derived 6 management options from the literature. These were (1) to treat all women with tocolytics and corticosteroids ("treat all"); (2) to treat all women while awaiting results of the "traditional" fetal fibronectin test results, then ...
متن کاملSonographic measurement of cervical length in threatened preterm labor in singleton pregnancies with intact membranes.
OBJECTIVES To predict when delivery will occur, within 48 h and 7 days of presentation and before 35 weeks' gestation in women presenting with threatened preterm labor. METHODS Sonographic measurement of cervical length was carried out in 510 women with singleton pregnancies presenting with threatened preterm labor and intact membranes at 24 to 33 + 6 weeks of gestation. The measurement was n...
متن کاملEffectiveness of a cervical pessary for women who did not deliver 48 h after threatened preterm labor (Assessment of perinatal outcome after specific treatment in early labor: Apostel VI trial)
BACKGROUND Preterm birth is a major cause of neonatal mortality and morbidity. As preventive strategies are largely ineffective, threatened preterm labor is a frequent problem that affects approximately 10 % of pregnancies. In recent years, risk assessment in these women has incorporated cervical length measurement and fetal fibronectin testing, and this has improved the capacity to identify wo...
متن کاملSonographic measurement of cervical length in twin pregnancies in threatened preterm labor.
OBJECTIVE To determine whether sonographic measurement of cervical length in twin pregnancies presenting with threatened preterm labor helps distinguish between true and false labor. METHODS In 87 women with twin pregnancies presenting with regular and painful uterine contractions at 24-36 (median, 30) weeks of gestation, cervical length was measured by transvaginal ultrasound. Women presenti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
دوره 27 4 شماره
صفحات -
تاریخ انتشار 2006