Inter-observer reproducibility of 15 tests used for predicting difficult intubation.
نویسندگان
چکیده
AIM To determine the inter-observer reproducibility of 15 tests used for predicting difficult tracheal intubation (DI). MATERIAL AND METHODS Following local ethics committee approval and informed consent, 101 volunteers were examined by two assessors using 15 tests for predicting DI. The two assessors who were blinded to the results of the other, examined each volunteer independently. Cohen's kappa (κ) or first-order agreement coefficient (AC1) were used to measure agreement between assessor ratings on a qualitative scale. Agreement between two quantitative outcomes was described using the intraclass correlation coefficient (ICC) and Pearson's (PCC) or Spearman's (SCC) correlation coefficients. The following interpretation of the coefficients was used: poor (< 0.20), fair (0.21-0.40), satisfactory (0.41-0.60), good (0.61-0.80), and excellent (0.81-1.00). RESULTS Respective coefficients of inter-rater agreement and correlation coefficients were determined for the following parameters: pathologies associated with DI (κ=0.662, AC1=0.990), clinical impression (κ=-0.013, AC1=0.969), modified Mallampati test (κ=0.503, AC1=0.861), upper lip bite test (κ=0.370, AC1=0.897), temporo-mandibular joint movement (κ=0.088, AC1=0.797), max. anteroflexion of C-spine (ICC=0.136, SCC=0.391), max. retroflexion of C-spine (ICC=0.020, SCC=0.284), mandibular length (ICC=0.301, SCC=0.553), neck circumference (ICC=0.832, SCC=0.928), hyo-mental distance (ICC=0.378, SCC=0.472), thyro-mental distance (ICC=-0.002, PCC=0.265), sternomental distance (ICC=0.674, PCC=0.815), and finally, inter-incisor gap (ICC=0.695, PCC=0.785). Two tests (positive history of DI and retrogenia), were excluded from calculation because no positive cases were found. CONCLUSION Best inter-rater agreement was found for the assessment of neck circumference while the highest discrepancies between raters were in goniometrically-measured mobility of the C-spine. Many of the pre-operative airway tests had only fair inter-observer reproducibility. This may be one reason why models for predicting difficult intubation are not universally reliable.
منابع مشابه
مقایسه دقت آزمون لب گزه (ULBT) با آزمون های فاصله دندان های ثنایا، تیرومنتال و استرنومنتال در ارزیابی راه هوایی فوقانی و پیش گویی لوله گذاری دشوار
Background: Difficult intubation (DI), often unexpected, remains a primary concern for anesthesiologists. The purpose of this study was to compare the sensitivity and specificity of ULBT with sternomental, thyromental and interincisor distances in predicting difficult intubation. Methods: In a prospective study, 380 patients undergoing general anesthesia were included. In all patients sternomen...
متن کاملمقایسه آزمون مالامپاتی در حالتهای نشسته و سوپاین به روش مرسوم و در حین آه کشیدن در پیشگویی لارنگوسکوپی و لولهگذاری مشکل
Background: Inadequate ventilation, esophageal intubation and difficult intubation are the most common adverse respiratory outcomes in patient undergoing anesthesia .The aim of this study was to compare Mallampati test in supine and sitting positions in traditional approach and during phonation for predicting difficult laryngoscopy and intubation. Methods: In this study performed in Imam Khomei...
متن کاملComparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment
Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...
متن کاملReproducibility of myocardial velocity and deformation imaging in term and preterm infants.
AIMS Myocardial velocity imaging has been validated in adults for assessment of ventricular function and indirect indices of pulmonary arterial pressure. To establish whether it could also be used in infants, we investigated the reproducibility of myocardial velocities and deformation indices in term and preterm neonates. METHODS AND RESULTS Myocardial velocity loops acquired from 16 infants ...
متن کاملبررسی کارایی و تکرار پذیری سیستم سیدنی در ارزیابی و درجهبندی گاستریت مزمن
Background and Aim: Chronic gastritis is one of the most common gastrointestinal disorders and detection of its etiology especially Helicobacter pylori and risk factors of malignancy (atrophy and intestinal metaplasia) is, to a great extent, based on histological assessment. Therefore, a system which could sustain good reproducibility in reporting observations is very important. Today, the mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia
دوره 155 3 شماره
صفحات -
تاریخ انتشار 2011