Quality of Diagnostic Studies
نویسنده
چکیده
I n this issue of the BJO (p 261), Siddiqui et al review the compliance of researchers with quality standards for evaluations of diagnostic test performance (DTP). ‘‘Standards’’ were originally set by the McMaster evidence based medicine (EBM) group 2 and they have continued to evolve over recent years. Unfortunately, the standards appear to have had little impact since reviews of recent evaluations have shown that they tend to be of poor quality, in medicine generally and in ophthalmology and other specialties. The review of Siddiqui et al confirms this gloomy picture. In contrast, during the same period, there has been substantial improvement in the quality and reporting of evaluations of the effectiveness of treatments. Why has research to evaluate DTP not benefited in a similar way from the EBM ‘‘movement’’? Perhaps improving the quality of research about effectiveness was seen as a priority because it was perceived to be important to patients—the ‘‘bit’’ of health care that makes them better—or because the resources wasted from using treatments that don’t work (and not using ones that do) was much easier for the public and media to appreciate. Perhaps the principles of high quality research to evaluate DTP are more difficult to grasp than controlled experiments to assess effectiveness. Or perhaps we can just blame Archie Cochrane! Whatever the reason, prioritising research about effectiveness might be seen as paradoxical since it is difficult to optimise treatment without first knowing the diagnosis. It is also not clearly justified on an efficiency basis, since substantial (and increasing) amounts of healthcare resources are spent on diagnosis, with new and expensive diagnostic technologies emerging. And the diversity of evidence about DTP is often not appreciated—for example, patients’ responses to standard questions when taking a history and standardised observations of clinical signs all constitute diagnostic ‘‘test’’ information, the value of which can be quantified. The relative neglect of evidence about DTP may, at last, be about to change. The Cochrane Collaboration has long appreciated the importance of such evidence—a methods groups on the topic was registered in 1995—and, in 2003, the collaboration took the decision to develop a new database of systematic reviews of diagnostic test accuracy. This will be developed in parallel with the existing database of systematic reviews of the effectiveness of healthcare interventions. This new review of ophthalmic tests might appear to suggest that things are improving compared to the situation during the 1990s. All evaluations scored some points, with scores ranging from 8–19/25 compared with 0–5/7. However, although all STARD items are important, they are not all equally important. Failure to report some item may mislead a reader but does not necessarily invalidate the evidence. In contrast, poor compliance in reporting particular items leads (on average) to biased, optimistic estimates of DTP. Unfortunately, compliance with these items, about masking/blinding (item 11) and workup bias (item 16), was poorer than for others, with 6/16 and 4/15 papers respectively judged to be compliant with the standard. Reporting indeterminate results (and analysing them correctly) is also crucial, since decisions still need to be made about patients who give such results. Failure to comply will almost always cause researchers to overestimate DTP. This item was poorly reported as well (item 22: 5/16).
منابع مشابه
ارزیابی مطالعات درستی آزمون تشخیصی
In the recent years, advances in different fields of technology have been resulted in a dramatic increase in the diagnostic methods and tests in different branches of clinical medicine with a consequent increase in the number of scientific publications related to the application of those tests and methods in the diagnosis or prevention of diseases. Dermatology is not an exception. Since, eviden...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملAssessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels
Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...
متن کاملQuality Assessment of Research Articles in Nuclear Medicine Using STARD and QUADAS-2 Tools
Objective(s): Diagnostic nuclear medicine is being increasingly employed in clinical practice with the advent of new technologies and radiopharmaceuticals. The report of the prevalence of a certain disease is important for assessing the quality of that article. Therefore, this study was performed to evaluate the quality of published nuclear medicine articles and determine the frequency of repor...
متن کاملAn Enumeration Survey on Diagnostic X-Ray Generators and Essential Safety Parameters in Mizoram, India
Introduction: Best radiography practice involves operational optimal machine performance, delivering cost-effective healthcare services under appropriate safety conditions for workers and the public. The present study aimed to investigate the safety status of diagnostic X-ray installations in Mizoram, India. Material and Methods: Lineari...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...
متن کامل