Incidence of microperforation for surgical gloves depends on duration of wear.
نویسندگان
چکیده
BACKGROUND The use of sterile gloves is part of general aseptic procedure, which aims to prevent surgical team members from transmitting infectious agents to patients during procedures performed in an operating room. In addition, surgical gloves also protect team members against patient-transmitted infectious agents. Adequate protection, however, requires that the glove material remain intact. The risk of perforations in surgical gloves is thought to correlate with the duration of wear, yet very few prospective studies have addressed this issue. METHODS We prospectively collected 898 consecutive pairs of used surgical gloves over a 9-month period in a single institution. After surgical team members wore the gloves during surgical procedures, the gloves were examined for microperforations using the watertight test described in European Norm 455, part 1. The gloves were analyzed as a pair; if 1 glove had a perforation, the pair was considered to be perforated. In addition, we evaluated the use of a hand cream that contained a suspension of cornstarch and ethanol to determine its potential influence on the rate of microperforation. RESULTS Wearing gloves for 90 minutes or less resulted in microperforations in 46 (15.4%) of 299 pairs of gloves, whereas wearing gloves for 91-150 minutes resulted in perforation of 54 (18.1%) of 299 pairs, and 71 of (23.7%) of 300 pairs were perforated when the duration of wear was longer than 150 minutes (P = .05). Subgroup analysis revealed no significant difference in the rates of microperforation for surgeons (56 [23.0%] of 244 pairs of gloves perforated), first assistants (43 [19.0%] of 226 pairs perforated), and surgical nurses (53 [20.5%] of 259 pairs perforated). Of 171 microperforations, 114 (66.7%) were found on the left hand glove (ie, the glove on subjects' nondominant hand), predominantly on the left index finger (55 [32.3%]). The use of the hand cream had no influence on the rate of microperforation. CONCLUSION Because of the increase in the rate of microperforation over time, it is recommended that surgeons, first assistants, and surgical nurses directly assisting in the operating field change gloves after 90 minutes of surgery.
منابع مشابه
Using a SCIP-PLUS perspective to reduce the risk of SSI
Methods Four risk reduction initiatives were studied, A: Impact of BMI on antimicrobial prophylactic dosing in general, OB and CT surgical patients; B: Development of standardized regimen of CHG preadmission cleansing to improve outcome in surgical patients; C: Efficacy of antimicrobial sutures to reduce the risk of suture contamination at wound closure and D: The impact of an innovative antimi...
متن کاملAntibacterial activity of a sterile antimicrobial polyisoprene surgical glove against transient flora following a 2-hours simulated use
BACKGROUND A surgical glove will protect surgeons and patients only if the glove's integrity remains intact. However, several studies have demonstrated that undetected micro-perforations of surgical gloves are common. Because of the possibility of surgical glove puncture, an antimicrobial surgical glove was developed. The aim of this laboratory based experimental study was to assess the antibac...
متن کاملNon-surgical management of microperforation induced by EMR of the stomach.
BACKGROUND Perforation and bleeding are major complications associated with gastric endoscopic mucosal resection. Evident perforation during endoscopic mucosal resection can be managed by endoscopic clipping. However, management of microperforation is not well established. PATIENT AND METHOD From January 2002 to June 2004, 109 early gastric cancers and 300 adenomas were treated with endoscopi...
متن کاملGlove Perforations during Oral & Maxillofacial Surgical Procedures
Seventy nine (13%) punctures were identified in 612 gloves. Gloves from the left hand showed the highest incidence of punctures. No puncture was observed in 100 gloves tested as a control. The results showed that glove puncture was more likely to occur in gloves worn on left (nonworking) hand overall as compared with gloves from the right hand. Gloves used for surgical procedures in which wires...
متن کاملGlove punctures in major and minor orthopaedic surgery with double gloving.
We assessed the frequency of glove perforation during major and minor orthopaedic surgeries, in order to determine the efficacy of double gloving. A total number of 1528 gloves (622 inner and 906 outer) used in 200 procedures (100 major-100 minor), and 100 pairs of unused gloves were examined. Glove perforation rate, incidence among surgical team, location of perforation and duration of surgery...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Infection control and hospital epidemiology
دوره 30 5 شماره
صفحات -
تاریخ انتشار 2009