MRI-Guided Prostate Motion Tracking using Multislice-to-Volume Registration
نویسنده
چکیده
MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this work: is rigid registration sufficient in tracking the targets with a maximum error of 3 mm (smaller than average prostate tumor size) and how many intra-operative slices are required to obtain this accuracy? We developed rigid and deformable multisliceto-volume registration algorithms for tracking the biopsy targets within the prostate. Three orthogonal plus additional transverse intra-operative slices were acquired in the approximate center of the prostate and registered with a high-resolution target planning volume. Simulated intra-operative data, phantom data, and MRI-guided robotic prostate biopsy data were used to assess tracking accuracy. Registration tests on simulated intra-operative data with 3, 4, and 5 slices were performed to evaluate the effect on registration error and time. Results: Using three orthogonal slices provides sufficient accuracy. Convergence test results on phantom images demonstrated 100% success rate for initial misalignment of 5mm. Average registration errors for the patient data were 2.55mm and 2.05mm for the rigid and deformable algorithms, respectively. The algorithm was able to capture rigid biopsy target displacements of maximum 8mm and non-rigid displacements of maximum 1.5mm. Rigid tracking appears to be promising. Deformable registration does not seem warranted. i
منابع مشابه
MRI-guided prostate motion tracking by means of multislice-to-volume registration.
We developed an algorithm for tracking prostate motion during MRI-guided prostatic needle placement, with the primary application in prostate biopsy. Our algorithm has been tested on simulated patient and phantom data. The algorithm features a robust automatic restart and a 12-core biopsy error validation scheme. Simulation tests were performed on four patient MRI pre-operative volumes. Three o...
متن کاملClosed-Loop Control in Fused MR-TRUS Image-Guided Prostate Biopsy
Multi-modality fusion imaging for targeted prostate biopsy is difficult because of prostate motion during the biopsy procedure. A closed-loop control mechanism is proposed to improve the efficacy and safety of the biopsy procedure, which uses real-time ultrasound and spatial tracking as feedback to adjust the registration between a preoperative 3D image (e.g. MRI) and real-time ultrasound image...
متن کاملDesign and Preliminary Accuracy Studies of an MRI-Guided Transrectal Prostate Intervention System
This paper reports a novel system for magnetic resonance imaging (MRI) guided transrectal prostate interventions, such as needle biopsy, fiducial marker placement, and therapy delivery. The system utilizes a hybrid tracking method, comprised of passive fiducial tracking for initial registration and subsequent incremental motion measurement along the degrees of freedom using fiber-optical encode...
متن کاملImage Registration and Fusion for Interventional MRI Guided Thermal Ablation of the Prostate Cancer
We are investigating interventional MRI (iMRI) guided thermal ablation treatment of the prostate cancer. Functional images such as SPECT can detect and localize tumor in the prostate not reliably seen in MRI. We intend to combine the advantages of SPECT with iMRI-guided treatments. Our concept is to first register the low-resolution SPECT with a high resolution MRI volume. Then by registering t...
متن کاملOptimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer
Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...