First Hybrid Images from a Combined PET and Field-Cycled MRI System

نویسندگان

  • G. A. Bindseil
  • W. B. Handler
  • T. J. Scholl
  • K. M. Gilbert
  • B. A. Chronik
چکیده

Introduction There is substantial interest in combining functional and anatomical imaging modalities into hybrid systems [1]. Efforts to combine PET and MRI must overcome the incompatibility of conventional PET detectors based on photomultiplier tubes (PMT) with magnetic fields. There are a number of approaches to PET and MRI modify PET detectors to make them compatible with conventional MRI [2,3]. A different approach is to use field-cycled MRI (FCMRI) with conventional PMT-based PET. In FCMRI, it is possible to rapidly turn all magnetic fields off enabling the use of PMT-based PET detectors [4,5]. The authors present the first dual modality image acquired on a combined PET and FCMRI system. Apparatus An FCMRI system with a 9-cm gap for PET detectors in the center of the scanner was used to generate MR images. The polarizing magnet (0.3 T) produces the initial magnetization of the sample. Then, standard MR imaging is done in the environment of a readout field (94 mT) with high spatial and temporal uniformity. The system has a full set of second-order shims to compensate for the increased inhomogeneity introduced by the PET gap and PET detectors. The geometry of the system is shown in Figure 1. All imaging was done with a low-pass birdcage RF coil tuned to operate at 4 MHz. The PET system consisted of two detectors taken from a clinical PET system placed 36 cm apart on opposite sides connected to coincidence detection hardware through an RF-shielded feed-through panel. Each PET detector consisted of four PMTs mated to a block of BGO scintillator cut into an array of 8x8 crystals each having a pitch 6.5 x 5.5 x 30 mm. The crystal array, cut to various depths, enabled position-determination of detected gamma rays through Anger logic. Methods A PET/MR phantom consisting of a triangular arrangement of point sources (Na-22, half-life 2.6 years, total activity 0.11 MBq, 10-mm separation between sources, 1-mm diameter per source, triangular casing with 1-inch side length) embedded in an onion (Figure 3, left) was used to test the feasibility of acquiring a PET and MR image simultaneously. The phantom was placed in the center of the field of view of both systems. To acquire PET data with two detectors for all lines of response (LOR), it was necessary to rotate the phantom (including RF coil) in 12 steps of 15 degrees and recombine the PET data post-acquisition. For consistency across all phantom rotation angles, PET and MR data were acquired in an interleaved sequence of approximately 0.75 Hz as shown in Figure 2. At each rotation step, a total of 2 minutes of PET data were recorded during a 32 minute MR sequence. The MR image from only the first rotation angle was kept. The MR imaging parameters were: 3D-FSE; BW = 20.03 kHz; FOV = 10x10x2 cm; ETL = 8; N AVG = 6; Imaging matrix = 192x128x6; TR/TE = 2752 ms/21 ms; TSCAN = 32 min; view = single transverse slice. Here, TR and TSCAN include PET acquisition stages. PET data were filtered using a 300-700 keV energy window and a 50-ns coincidence-timing window, yielding 120,000 counts. The sinogram was reconstructed using filtered back-projection with no attenuation correction, and two iterations of smoothing (linear interpolation) were applied to the image. Results Figure 3 (right) shows a superposition of PET and MR images acquired in an interleaved manner on the PET/FCMRI system. There are no major streak artifacts in the PET image. There are also no significant phase encoding or ghosting artifacts in the MR image. Since the field-cycled MR system images at low field, there are no apparent susceptibility artifacts due to the presence of the solid radioactive sources. The resolution of the PET image is limited by the size of the clinical PET detectors, which have coarse position determination compared with modern small-animal PET detectors. Also, the higher reconstructed activity of the lower right point source compared with the others is due to the oversampling of the center of the FOV that occurs when only two detectors are used via a known mechanism. The lower right source was closest to the center of the PET FOV. Layers of the onion are apparent in the MR image. On the reverse side of the triangular source, a small section of onion protruded into the interior of the triangular hole and is visible in the top left edge of the hole in the MR image. Discussion The successful generation of the first dual modality PET/FCMRI image motivates the authors to pursue the development of an integrated PET/FCMRI system using more appropriate highperformance microPET technology for small-animal imaging with FCMRI at higher fields [6].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Hybrid imaging with PET/CT and PET/MR

Hybrid PET/MRI systems have recently become commercially available with potential to change medical imaging by providing combined anatomical-metabolic image information. Especially in cancer patients, this may be of benefit. PET itself is widely used in everyday routine due to its capability of providing molecular information used mainly for the non-invasive characterization of tumors and metas...

متن کامل

Automated Detection of Multiple Sclerosis Lesions Using Texture-based Features and a Hybrid Classifier

Background: Multiple Sclerosis (MS) is the most frequent non-traumatic neurological disease capable of causing disability in young adults. Detection of MS lesions with magnetic resonance imaging (MRI) is the most common technique. However, manual interpretation of vast amounts of data is often tedious and error-prone. Furthermore, changes in lesions are often subtle and extremely unrepresentati...

متن کامل

Quantitative, simultaneous PET/MRI for intratumoral imaging with an MRI-compatible PET scanner.

UNLABELLED Noninvasive methods are needed to explore the heterogeneous tumor microenvironment and its modulation by therapy. Hybrid PET/MRI systems are being developed for small-animal and clinical use. The advantage of these integrated systems depends on their ability to provide MR images that are spatially coincident with simultaneously acquired PET images, allowing combined functional MRI an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008