Impact of sensor and measurement timing errors on model-based insulin sensitivity

نویسندگان

  • Christopher G. Pretty
  • Matthew Signal
  • Liam M. Fisk
  • Sophie Penning
  • Aaron J. Le Compte
  • Geoffrey M. Shaw
  • Thomas Desaive
  • J. Geoffrey Chase
چکیده

A model-based insulin sensitivity parameter (SI) is often used in glucose-insulin system models to define the glycaemic response to insulin. As a parameter identified from clinical data, insulin sensitivity can be affected by blood glucose (BG) sensor error and measurement timing error, which can subsequently impact analyses or glycaemic variability during control. This study assessed the impact of both measurement timing and BG sensor errors on identified values of SI and its hour-to-hour variability within a common type of glucose-insulin system model. Retrospective clinical data were used from 270 patients admitted to the Christchurch Hospital ICU between 2005 and 2007 to identify insulin sensitivity profiles. We developed error models for the Abbott Optium Xceed glucometer and measurement timing from clinical data. The effect of these errors on the re-identified insulin sensitivity was investigated by Monte-Carlo analysis. The results of the study show that timing errors in isolation have little clinically significant impact on identified SI level or variability. The clinical impact of changes to SI level induced by combined sensor and timing errors is likely to be significant during glycaemic control. Identified values of SI were mostly (90th percentile) within 29% of the true value when influenced by both sources of error. However, these effects may be overshadowed by physiological factors arising from the critical condition of the patients or other under-modelled or un-modelled dynamics. Thus, glycaemic control protocols that are designed to work with data from glucometers need to be robust to these errors and not be too aggressive in dosing insulin.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FEM Updating of Ship Structure by The Sensitivity Equation of Transmissibility Function

This study presents a novel sensitivity-based finite element model updating approach to estimate structural parameters using output-only data. A quasi-exact sensitivity relation based on transmissibility data is introduced. Partially measured structural responses are included in mathematical formulations to address incomplete measurement problems and improve the accuracy of the sensitivity rela...

متن کامل

A New Fault Tolerant Nonlinear Model Predictive Controller Incorporating an UKF-Based Centralized Measurement Fusion Scheme

A new Fault Tolerant Controller (FTC) has been presented in this research by integrating a Fault Detection and Diagnosis (FDD) mechanism in a nonlinear model predictive controller framework. The proposed FDD utilizes a Multi-Sensor Data Fusion (MSDF) methodology to enhance its reliability and estimation accuracy. An augmented state-vector model is developed to incorporate the occurred senso...

متن کامل

Spatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy

The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...

متن کامل

Error Recovery by the Use of Sensory Feedback and Reference Measurements for Robotic Assembly

Industrial robots need instrument or parts transport to do which requires coordinate to show the robot’s instrument, parts and body. When investigating the robot location, we are usually interested in measuring its location relative to a reference coordinate system. In this system it is attempted to make the assemble direction smaller by designing the sensor board and making use of an instrumen...

متن کامل

A New Structure for Direct Measurement of Temperature Based on Negative Temperature Coefficient Thermistor and Adaptive Neuro-fuzzy Inference System

Thermistors are very commonly used for narrow temperature-range high-resolution applications, such as in medicine, calorimetry, and near ambient temperature measurements. In particular, Negative Temperature Coefficient (NTC) thermistor is very inexpensive and highly sensitive, whose sensing temperature range and sensitivity are highly limited due to the intrinsic nonlinearity and self-heating p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 114 3  شماره 

صفحات  -