Online automatic discrimination between solid and gaseous cerebral microemboli with the first multifrequency transcranial Doppler.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The aim of this study was to assess the first multifrequency transcranial Doppler system that was specially developed to automatically detect and discriminate between solid and gaseous cerebral microemboli. METHODS The multifrequency transcranial Doppler instrumentation insonates simultaneously with 2.5 and 2.0 MHz. Differentiation between solid and gaseous microemboli is based on the principle that solid microemboli reflect more ultrasound at the higher than at the lower frequency, whereas the opposite is the case for gaseous microemboli. In the in vitro studies, 159 plastic spheres (50 or 80 micro m in diameter) and 105 gas bubbles (8 to 25 micro m) were studied in a pulsatile closed-loop system containing irodinium or pig blood. In vivo studies were carried out for 1 hour in 15 patients with mechanical heart valves and in 45 patients with carotid stenosis. This gave a total of 60 hours of online automatic monitoring in patients. RESULTS In the in vitro studies, 152 of the 159 (95.6%) plastic spheres were classified as solid, and 7 (4.4%) were classified as uncertain solid. Of the 105 gas bubbles, 99 (94.3%) were classified as gaseous and 6 (5.7%) as uncertain gaseous. Thus, correct classification was made for 251 (95.1%) of the 264 embolic events studied. A comparison between the automatic multifrequency discrimination and the known embolic classification gave a kappa value of 0.897 (P<0.0001). The multifrequency Doppler classified 433 (84.2%) of the 514 emboli detected in the mechanical heart valve patients as gaseous, 74 (14.4%) as solid, and 7 (1.4%) as uncertain (3 uncertain solid, 4 uncertain gas). Thirty-two emboli were detected in 17 (38%) of the 45 carotid stenosis patients; 30 (93.7%) were classified as solid and 2 (6.3%) as uncertain solid. CONCLUSIONS This study has shown that multifrequency transcranial Doppler can be used to automatically differentiate between solid and gaseous microemboli online. Most detected microemboli in this initial study of mechanical heart valves were classified as gaseous, whereas most were classified as solid in the patients with carotid stenosis.
منابع مشابه
Automatic online embolus detection and artifact rejection with the first multifrequency transcranial Doppler.
BACKGROUND AND PURPOSE The goal of this study was to assess the first multifrequency transcranial Doppler system specially developed for online automatic detection of cerebral microemboli. METHODS The multifrequency Doppler instrumentation insonates simultaneously with 2.0- and 2.5-MHz frequencies. The detection threshold for embolus detection used in this study was a relative Doppler energy ...
متن کاملSolid cerebral microemboli and cerebrovascular symptoms in patients with prosthetic heart valves.
BACKGROUND AND PURPOSE Although cerebral microemboli are often detected by transcranial Doppler ultrasonography in mechanical heart valve patients, the clinical significance of such microemboli is unclear. The aim of this study was to determine the frequency and composition of cerebral microemboli in a prosthetic heart valve population and to correlate these findings to cerebrovascular symptoms...
متن کاملCan transcranial Doppler discriminate between solid and gaseous microemboli? Assessment of a dual-frequency transducer system.
BACKGROUND AND PURPOSE Transcranial Doppler ultrasound can reliably detect both gaseous and solid cerebral emboli. However, conventional equipment is unable to discriminate between gaseous and solid emboli. This is a major limitation in situations in which the 2 coexist, because they may have very different clinical relevance. Recently, a novel Embo-Dop system, using insonation at 2 ultrasound ...
متن کاملCerebral microemboli and brain injury during carotid artery endarterectomy and stenting.
BACKGROUND AND PURPOSE Cerebral microembolic signals detected by transcranial Doppler are frequent during carotid angioplasty with stenting and carotid endarterectomy (CEA). Their potential harmful effects on the brain are, however, unclear. The aim of this study was to relate the frequency and type of per-procedural microembolic signals to procedure-related ipsilateral ischemic strokes and new...
متن کاملCerebral emboli during left heart catheterization may cause acute brain injury.
AIMS Left heart catheterization carries a risk for cerebral complications. The aims of this prospective study were to determine the frequency and composition of catheterization-related cerebral microemboli and to detect cerebral morphological changes and acute cognitive impairment due to catheterization. METHODS AND RESULTS Forty-seven unselected patients undergoing elective left heart cathet...