Progress report on the MindView brain PET detector module based on large area SiPMs arrays

نویسندگان

  • Antonio J González
  • Stan Majewski
  • Pablo Conde
  • Liczandro Hernández
  • Filomeno Sánchez
  • Pablo Bellido
  • Efrén Crespo
  • Amadeo Iborra
  • Laura Moliner
  • Juan P Rigla
  • Maria J Rodríguez-Álvarez
  • Michael Seimetz
  • Antonio Soriano
  • Alexander Stolin
  • Luis F Vidal
  • José M Benlloch
چکیده

Institute for Instrumentation in Molecular Imaging, CSIC-UPV, Valencia, Spain The main technical goal of the MindView project and, thus, the subject of this contribution, is achieving simultaneous PET/MR imaging, dedicated to brain examination in clinical research settings to study psychiatric disorders. The system will allow visualization of the relevant structures in the brain with very high resolution (~1mm) and sensitivity. This brain PET will be mounted together with a bird-cage type TR RF-coil. An effective combined PET/RF aperture of 27 cms will be generated. Preliminary detector head tests have been carried out with standard arrays of 12x12 SiPMs of the type FB-30035 from SensL. Several crystal configurations, including small size crystal arrays but also thick monolithic slabs, have been tried with the goal to optimize the best trade-off detector performance. The chosen readout electronics is based on a diode network capable to return independent information about each matrix row and column signals. Therefore, up to 24 outputs can be currently considered for the photon impact reconstruction within the crystal. In the pilot test with the 10 mm thick LYSO crystal array of ~1.5 mm pitch pixels covering the entire 5x5 cm photosensor area are seen very well resolved, including the corners. Energy resolutions of individual crystal pixels as good as 10 % are achieved. The detector assembly was typically run at a stable environment temperature of 10-15 Celsius and at 29.5 ± 1.0 Vop bias voltage (~5 V overvoltage). Additionally to these tests, it has also been shown that the system has capability to resolve two staggered layers of 1.5 mm pixel size crystals. The study continues with more layers in the stack. The MRI compatibility of the SensL SiPMs was shown in during the tests in a 3 Tesla MRI @WVU. Development of MRI compatible circuitry (printed circuits and connectors, etc) is in progress.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of large-area, low-noise, arrays of SiPMs.

Institute for Instrumentation in Molecular Imaging, I3M-CSIC, Valencia, Spain In this work we present the first evaluation results of an array of 12x12 SiPMs MicroFC-30035-SMT from SensL. These sensors are basically identical to those custom fabricated for the brain PET insert of the MindView project, except for the larger package. Both the C-Series and MindView parts are built with the same pr...

متن کامل

A large area, silicon photomultiplier-based PET detector module.

The introduction of silicon photomultipliers (SiPM) has facilitated construction of compact, efficient and magnetic field-hardened positron emission tomography (PET) scanners. To take full advantage of these devices, methods for using them to produce large field-of-view PET scanners are needed. In this investigation, we explored techniques to combine two SiPM arrays to form the building block f...

متن کامل

The MINDView brain PET detector, feasibility study based on SiPM arrays

The Multimodal Imaging of Neurological Disorders (MINDView) project aims to develop a dedicated brain Positron Emission Tomography (PET) scanner with sufficient resolution and sensitivity to visualize neurotransmitter pathways and their disruptions in mental disorders for diagnosis and follow-up treatment. The PET system should be compact and fully compatible with a Magnetic Resonance Imaging (...

متن کامل

A compact PET detector module using SiPMs and MVT digitizers

Huazhong University of Science & Technology, Hubei, China Nowadays the simultaneous PET/MRI is being paid more and more attentions. Since MRI provides a high resolution, unsurpassed soft tissue contrast imaging and PET reveal the metabolism progress in molecular level, it is reasonable to believe the PET/ MRI will be a powerful tool to improve the understanding of pathogenesis and mechanism of ...

متن کامل

Depth of interaction determination in monolithic scintillator with double side SiPM readout

BACKGROUND Monolithic scintillators read out by arrays of photodetectors represent a promising solution to obtain high spatial resolution and the depth of interaction (DOI) of the annihilation photon. We have recently investigated a detector geometry composed of a monolithic scintillator readout on two sides by silicon photomultiplier (SiPM) arrays, and we have proposed two parameters for the D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014