Nasal pressure recording in the diagnosis of sleep apnoea hypopnoea syndrome.

نویسندگان

  • F Sériès
  • I Marc
چکیده

BACKGROUND Nasal pressure tracing is now being used to measure breathing in ambulatory screening devices for sleep apnoea but it has not been compared with other methods of assessment. METHODS Sleep induced breathing disorders were scored by three different methods of analysis (thermistry, inductive plethysmography, and nasal pressure tracing) in 193 consecutive patients referred to our sleep laboratory. With the conventional thermistry method an apnoea was defined as the absence of oronasal flow on the thermistor signal for >/=10 s and a hypopnoea as a 50% decrease in the sum signal of inductive plethysmography tracing for >/=10 s associated with an arousal and/or a 2% decrease in SaO2. Nasal pressure was measured via nasal prongs connected to a pressure transducer. Using the thermistor signal alone, a hypopnoea was defined as a 50% decrease in the signal for >/=10 s associated with an arousal and/or a 2% decrease in SaO2. A similar definition of apnoea and hypopnoea was used for nasal pressure, the fall in pressure being substituted for the thermistor reading. RESULTS Impaired nasal ventilation prevented adequate measurements of nasal pressure in 9% of subjects. According to the conventional method of interpretation 107 subjects were identified as having the sleep apnoea hypopnoea syndrome (SAHS). The apnoea + hypopnoea index (AHI) was significantly lower using the thermistry method than with conventional analysis (mean difference -4.3/h, 95% CI -5.3 to -3.2, p<10(-4)); 39% of conventional hypopnoeic events were scored as apnoeas using nasal pressure scoring. Apnoeic and hypopnoeic events could also be observed without any change in thermistor and sum Respitrace signals that resumed with the occurrence of arousals or awakenings. The AHI was significantly higher with nasal pressure scoring than with the conventional method (mean difference 4.5, 95% CI 3.4 to 5.6, p<10(-4)). The mean difference in apnoea index between conventional and nasal pressure scoring was -7.5/h (95% CI -8.9 to -6.1). In the 78 patients who did not have SAHS according to the conventional method of analysis there was a significant positive relationship between the arousal index and AHI measured by nasal pressure tracing (R = 0.51, p<10(-4)). Seventeen of the 78 patients had an AHI of >15/h by the nasal pressure method of analysis. CONCLUSIONS Nasal pressure recording provides a simple and reliable measurement of nocturnal breathing abnormalities and may identify breathing abnormalities associated with arousals that are missed by other diagnostic methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive role of nasal functionality tests in the evaluation of patients before nocturnal polysomnographic recording

Obstructive sleep apnoea syndrome is a disease characterized by a collapse of the pharyngeal airway resulting in repeated episodes of airflow cessation, oxygen desaturation, and sleep disruption. It is a common disorder affecting at least 2-4% of the adult population. The role of nasal resistance in the pathogenesis of sleep disordered breathing and sleep apnoea has not been completely clarifie...

متن کامل

Value of beat-to-beat blood pressure changes, detected by pulse transit time, in the management of the obstructive sleep apnoea/hypopnoea syndrome.

Two important aspects of a respiratory sleep study are a measure of inspiratory effort and an estimate of the number of arousals. These can be derived from an indirect estimate of beat-to-beat blood pressure (BP), pulse transit time (PTT). This study investigated the reproducibility of inspiratory BP falls (reflecting inspiratory effort), and BP arousals derived from PTT, and the contribution t...

متن کامل

Adequacy of prescribing nasal continuous positive airway pressure therapy for the sleep apnoea/hypopnoea syndrome on the basis of night time respiratory recording variables.

BACKGROUND The increased demand of full polysomnographic studies, not only for diagnostic purposes but also for continuous positive airway pressure (CPAP) titration, has produced long waiting lists. Simpler methods are therefore needed to avoid having to refer all patients for full polysomnography. The hypothesis that CPAP therapy for the sleep apnoea/hypopnoea syndrome (SAHS) can be performed ...

متن کامل

Influence of correction of flow limitation on continuous positive airway pressure efficiency in sleep apnoea/hypopnoea syndrome.

We evaluated the efficiency of two different treatment procedures with continuous positive airway pressure (CPAP) on sleep, nocturnal breathing characteristics and daytime vigilance in 18 newly diagnosed patients with untreated sleep apnoea/hypopnoea syndrome (SAHS) randomly allocated to two different groups. In group I, the positive pressure (PP) level was set to suppress flow limitation (PFL)...

متن کامل

REVIEW SERIES Sleep ? 9: An approach to treatment of obstructive sleep apnoea/hypopnoea syndrome including upper airway surgery

This article provides an overview of the management of the obstructive sleep apnoea/hypopnoea syndrome (OSAHS). Where possible, recommendations are based on a review of the relevant literature. With the exception of nasal continuous positive airway pressure, which is considered in greater detail elsewhere in the series, and certain oral appliances, the efficacy of many proposed treatments for O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thorax

دوره 54 6  شماره 

صفحات  -

تاریخ انتشار 1999