Comparison of radioimmunoassay and enzyme-linked immunoassay methods for detection of Histoplasma capsulatum var. capsulatum antigen.

نویسندگان

  • M M Durkin
  • P A Connolly
  • L J Wheat
چکیده

The purpose of this study was to compare the conventional radioimmunoassay (RIA) to an enzyme-linked immunoassay (EIA) for the measurement of Histoplasma antigen in banked urine specimens. A correlation between the two methods would allow the EIA to be used as a nonradioactive alternative to the established 125I RIA. The study used stored urine from patients diagnosed with histoplasmosis during an outbreak in Indianapolis which began in 1988. Control specimens from healthy adults, patients with other fungal infections, urinary tract infections, or nonfungal pneumonia were also tested. Both the RIA and EIA were run concurrently. The RIA system measured antigen levels of 0.4 to 27.0 RIA units, while the EIA measured antigen levels of 0.6 to 20.1 units. Both the EIA and RIA detected measurable antigen levels in urine from 50 of 56 patients (89%) with disseminated disease and 11 of 30 patients (37%) with self-limiting disease. One of 96 control specimens, from a patient with paracoccidioidomycosis, was positive with both systems. Antigen levels measured by EIA correlated well with those measured by the established RIA method (correlation coefficient, 0.974). The EIA is an acceptable alternative to the RIA for measuring Histoplasma antigen levels in urine specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of an enzyme immunoassay for detection of Histoplasma capsulatum antigen from urine specimens.

Detection of Histoplasma capsulatum urinary antigen (UAg) is important for the initial diagnosis of infection and for monitoring of patient responses to antifungal therapy. This study evaluated an analyte-specific reagent (ASR) enzyme immunoassay (EIA) for the detection of H. capsulatum UAg from Immuno Mycologics, Inc. (IMMY) (Norman, OK) in comparison with routine testing with the MiraVista (M...

متن کامل

Cranial and Spinal Locations of Histoplasma capsulatum ‎var. duboisii in Brazzaville‎

Background: Histoplasma capsulatum var. duboisii is a rare fungus, endemic in southern Africa of the Sahara and Madagascar.  Objective: To describe the confirmed cases of histoplasmosis. Methods: This retrospective study was conducted at the division of neurosurgery of Brazzaville academic hospital in the Republic of Congo. Clinical records of all confirmed cases who were admitted between Jan...

متن کامل

Performance characteristics of a polyclonal enzyme immunoassay for the quantitation of Histoplasma antigen in human urine samples.

An antigen detection assay was prepared with rabbit anti- Histoplasma antibodies to detect and quantitate Histoplasma capsulatum antigen in urine samples. By using a 4-parameter curve fit, the assay calibration ranges from 2 to 1,000 enzyme immunoassay (EIA) units. We compared results for 99 urine samples with those of a reference laboratory, half of which tested positive or equivocal by that r...

متن کامل

PCR assay for identification of histoplasma capsulatum based on the nucleotide sequence of the M antigen.

The major diagnostic antigens of Histoplasma capsulatum var. capsulatum are the H and M antigens, pluripotent glycoproteins that elicit both humoral and T-cell-mediated immune responses. The gene encoding the M antigen has previously been sequenced, and its sequence has significant overall homology to those of the genes for fungal catalases. Regions of the M-antigen gene with little or no homol...

متن کامل

Production and evaluation of reagents for detection of Histoplasma capsulatum antigenuria by enzyme immunoassay.

The detection of urinary Histoplasma capsulatum polysaccharide antigen (HPA) by enzyme immunoassay (EIA) has proven useful for the presumptive diagnosis of histoplasmosis in AIDS patients. Assay limitations include (i) detection of a largely uncharacterized antigen and (ii) difficulty in reproducibly generating antibodies for use in the EIA. To improve antibody production for use in this test a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 9  شماره 

صفحات  -

تاریخ انتشار 1997