Selective Automated Perimetry Under Photopic, Mesopic, and Scotopic Conditions: Detection Mechanisms and Testing Strategies.

نویسندگان

  • Matthew P Simunovic
  • Anthony T Moore
  • Robert E MacLaren
چکیده

PURPOSE Automated scotopic, mesopic, and photopic perimetry are likely to be important paradigms in the assessment of emerging treatments of retinal diseases, yet our knowledge of the photoreceptor mechanisms detecting targets under these conditions remains largely dependent on simian data. We therefore aimed to establish the photoreceptor/postreceptoral mechanisms detecting perimetric targets in humans under photopic, mesopic, and scotopic conditions and to make recommendations for suitable clinical testing strategies for selective perimetry. METHODS Perimetric sensitivities within 30° of fixation were determined for eight wavelengths (410, 440, 480, 520, 560, 600, 640, and 680 nm) under scotopic, mesopic (1.3 cd.m-2) and photopic (10 cd.m-2) conditions. Data were fitted with vector combinations of rod, S-cone, nonopponent M+L-cone mechanism, and opponent M- versus L-cone mechanism templates. RESULTS Scotopicperimetric sensitivity was determined by rods peripherally and by a combination of rods and cones at, and immediately around, fixation. Mesopic perimetric sensitivity was mediated by M+L-cones and S-cones centrally and by M+L-cones and rods more peripherally. Photopic perimetric sensitivity was determined by an opponent M- versus L-cone, a nonopponent M+L-cone, and an S-cone mechanism centrally and by a combination of an S-cone and an M+L-cone mechanism peripherally. CONCLUSIONS Under scotopic conditions, a 480-nm stimulus provides adequate isolation (≥28 dB) of the rod mechanism. Several mechanisms contribute to mesopic sensitivity: this redundancy in detection may cause both insensitivity to broadband white targets and ambiguity in determining which mechanism is being probed with short-wavelength stimuli. M- and L-cone-derived mechanisms are well isolated at 10 cd.m-2: these may be selectively probed by a stimulus at 640 nm (≥ 20 dB isolation). TRANSLATION RELEVANCE In human observers, multiple mechanisms contribute to the detection of Goldmann size III and size V perimetric targets under scotopic, mesopic, and photopic conditions. The relative contribution of these mechanisms appears to differ from those found previously for macaques. Our results furthermore suggest that caution must be exercised when using microperimetric techniques, which are typically conducted under mesopic conditions and which are likely to be important in the assessment of emerging treatments for retinal disease. This is because mesopic background conditions maximize the redundancy of target detection. Furthermore, our results demonstrate that spectral manipulation of the stimulus alone cannot be used to reliably separate rod from cone responses under these conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion processing at low light levels: Differential effects on the perception of specific motion types.

While many aspects of human vision at low light levels have been studied in great detail, motion perception has rarely been investigated so far. Here we address differential effects of light level on the perception of coherent motion, heading from radial flow, and biological motion. We determined detection thresholds under photopic, mesopic, and scotopic conditions. Results indicate that the pe...

متن کامل

Asymmetrical Functional Deficits of ON and OFF Retinal Processing in the mdx3Cv Mouse Model of Duchenne Muscular Dystrophy.

Purpose The dystrophin mouse mutant mdx3Cv exhibits scotopic electroretinograpic (ERG) abnormalities, which resemble clinical changes observed in Duchenne muscular dystrophy (DMD) patients. In the present study, ERGs obtained from mdx3Cv and their wild-type littermates under scotopic, mesopic, and photopic conditions were analyzed to provide further insight on the affected retinal pathways, and...

متن کامل

Reduced mesopic and photopic foveal contrast sensitivity in glaucoma.

OBJECTIVE To demonstrate differences in foveal contrast sensitivity (CS) between glaucomatous and nonglaucomatous eyes using a simple, rapid computerized test. METHODS This study included consecutive patients with glaucoma (35 eyes) and age-matched control participants (23 eyes) with visual acuity of 20/30 or better. Patients with any other ocular disease, including cataract, were excluded. A...

متن کامل

Multifocal vs Monovision - thru-luminance (scotopic-mesopic-photopic) comparison of two presbyopia correction ways

Purposes: a) comparison of two presbyopia correction methods – with multifocal and monovision contact lenses – by means of precise contrast sensitivity measuring under scotopic, mesopic and photopic conditions simultaneously; b) new computerized AltTechNV Thru‐luminance CSF test trial operation. Methods: contrast sensitivity of 14 initial presbyopes (40÷51 y.o., never wore contact lenses, use...

متن کامل

Physiologic anisocoria under various lighting conditions

Purpose To evaluate the measurement of anisocoria in a group of ocular healthy subjects using a standardized protocol in scotopic, mesopic, and photopic lighting conditions, and determine the optimal threshold of difference in pupil diameter in determining physiologic anisocoria. Methods Right and left pupil diameters of 126 ocular healthy subjects with a mean age 30.5±7.8 years (40 males and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2016