Dmd066308 137..150

نویسندگان

  • Junko Sugatani
  • Yuji Noguchi
  • Yoshiki Hattori
  • Masahiko Yamaguchi
  • Yasuhiro Yamazaki
  • Akira Ikari
چکیده

ThehumanpregnaneX receptor (hPXR) is a xenobiotic-sensing nuclear receptor that transcriptionally regulates drug metabolism–related genes. The aim of the present study was to elucidate the mechanism by which hPXR is regulated through threonine-408. A phosphomimetic mutationat threonine-408 (T408D) reduced the transcriptional activity of hPXR and its protein stability in HepG2 and SW480 cells in vitro and mouse livers in vivo. Proteasome inhibitors (calpain inhibitor I and MG132) and Hsp90 inhibitor geldanamycin, but not Hsp70 inhibitor pifithrin-m, increased wild-type (WT) hPXR in the nucleus. The translocation of the T408D mutant to the nucleus was significantly reduced even in the presence of proteasome inhibitors, whereas the complex of yellow fluorescent protein (YFP)-hPXR T408D mutant with heat shock cognate protein 70/heat shock protein 70 and carboxy terminusHsp70interacting protein (CHIP; E3 ligase) was similar to that of the WT in the cytoplasm. Treatment with pifithrin-m and transfection with anti-CHIP small-interfering RNA reduced the levels of CYP3A4 mRNA induced by rifampicin, suggesting the contribution of Hsp70 and CHIP to the transactivation of hPXR. Autophagy inhibitor 3-methyladenine accumulated YFP-hPXR T408D mutant more efficiently than the WT in the presence of proteasome inhibitor lactacystin, and the T408D mutant colocalized with the autophagy markers, microtubule-associated protein 1 light chain 3 and p62, which were contained in the autophagic cargo. Lysosomal inhibitor chloroquine caused the marked accumulation of the T408D mutant in the cytoplasm. Protein kinase C (PKC) directly phosphorylated the threonine-408 of hPXR. These results suggest that hPXR is regulated through its phosphorylation at threonine-408 by PKC, CHIP/chaperone–dependent stability check, and autophagic degradation pathway.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Elaboration Likelihood Model of Persuasion

A. ArgumentIMessage Quality ........ ................................. 132 B. Peripheral Cues.. . . . . . . . . . . . . . . . . ................................. 134 C. Affecting Elaboration . . . . . . . . . . . . . ................................. 136 V. Postulate 4 Objective Elaboration.. ............................. . . . . . . . 137 A. Distraction ...........................................

متن کامل

P - 9 Patterns of visual field defect in CNS demyelinating diseases

S Multiple Sclerosis 2009; 15: 137–150 © 2009 SAGE Publications 10.1177/1352458508099417 Los Angeles, London, New Delhi and Singapore Poster Session 1 Epidemiology & Registry

متن کامل

Thomas A. Edison: Sketch of Activities, 1874-1881.

Thomas A. Edison: Sketch of Activities, 1874-1881: Norman R. Speiden ...................................... 137 Thomas A. Edison and the Founding of Science: 1880 ............ 142 Thomas A. Edison and the Naval Research Laboratory: A. Hoyt Taylor ......................................... 148 The Nature and Development of Operations Research: Charles Kittel. 150 Patent Policies in Educational In...

متن کامل

Infant Visual Perception

THEORIES OF PERCEPTUAL DEVELOPMENT 110 The Constructivist View 110 The Ecological View 112 The Contemporary Situation in Perceptual Theory 113 BASIC VISUAL SENSITIVITIES IN INFANCY 114 Visual Acuity 114 Contrast Sensitivity 116 Orientation Sensitivity 119 Pattern Discrimination 119 Color Vision 120 Motion Perception 124 SPACE PERCEPTION 126 Kinematic Information 127 Stereoscopic Depth Perceptio...

متن کامل

Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams

Air kerma calibration coefficients for a reference class ionization chamber from narrow x-ray spectra and cesium 137 gamma-ray beams were compared between the National Institute of Standards and Technology (NIST) and the Kenya Bureau of Standards (KEBS). A NIST reference-class transfer ionization chamber was calibrated by each laboratory in terms of the quantity air kerma in four x-ray referenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015