Radionuclide plethysmography for noninvasive evaluation of peripheral arterial blood flow.
نویسندگان
چکیده
We validated a noninvasive radionuclide plethysmography technique to evaluate peripheral arterial blood flow during reactive hyperemia. This method, based on the measurement of blood volume variations during repetitive venous occlusions, was compared with strain-gauge venous impedance plethysmography. The technique uses 99mTc-labeled autologous red blood cells scintigraphy to determine the rate of change of forearm scintigraphic counts during venous occlusion. Thirteen subjects were simultaneously evaluated with radionuclide and impedance plethysmography. Six baseline flow measurements were performed to evaluate the reproducibility of each method. Twenty-seven serial measurements were then made to evaluate flow variation during forearm reactive hyperemia. After 30 min of recovery, resting forearm blood flows were again evaluated. Impedance and radionuclide methods showed excellent reproducibility with intraclass correlation coefficients of 0.96 and 0.93, respectively. There was also good correlation of flows between both methods during reactive hyperemia (r = 0.87). Resting flows at 30 min after reactive hyperemia were slightly lower than at baseline with both methods. We conclude that radionuclide plethysmography could be used for the noninvasive evaluation of forearm blood flow and its dynamic variations during reactive hyperemia.
منابع مشابه
بررسی تأثیر Vacuum-Compression Therapy (VCT) بر جریان خون اندام دیابتی
Background: Chronic diabetes is substantially associated with circulatory disorders in lower limbs. Vacuum-Compression Therapy (VCT) has been commonly used in treatment of peripheral circulatory disorders. VCT is based on intermittent alteration of Positive- Negative pressure phases. The purpose of this study was to determine effects of VCT on diabetic subjects' peripheral blood flow.Methods: I...
متن کاملSeventy-five Years of Use of Impedance Plethysmography in Physiological Data Acquisition and Medical Diagnostics
Impedance plethysmography (IPG) came into existence in 1940 as a result of Jan Nyboer’s pioneering work in the noninvasive assessment of central and peripheral blood flow. The technique got an impetus after introduction first-time derivative of the impedance for accurate determination of stroke volume (SV) and various cardiac intervals. Later, this signal was employed by Parulkar et al for esti...
متن کاملCold pressor test using strain-gauge plethysmography.
This laboratory activity is designed to teach students how to measure forearm muscle blood flow (FBF) to describe the mechanisms of peripheral blood flow thermal regulation in healthy subjects. The cold pressor test (CPT) is the clinical procedure used in the experiment to induce arterial vasoconstriction. Strain-gauge plethysmography is applied on the patient's forearm to noninvasive monitor v...
متن کاملGuidelines for Noninvasive Vascular Laboratory Testing: A Report from the American Society of Echocardiography and the Society of Vascular Medicine and Biology
Accompanying the rapid growth of interest in percutaneous vascular interventions, there has been increasing interest among cardiologists in performing noninvasive vascular testing using ultrasound. In an attempt to provide recommendations on the best practices in vascular laboratory testing, this report has been prepared by a writing group from the American Society of Echocardiography (ASE) and...
متن کاملSplanchnic hyperemia and hypervolemia during Valsalva maneuver in postural tachycardia syndrome.
Prior work demonstrated dependence of the change in blood pressure during the Valsalva maneuver (VM) on the extent of thoracic hypovolemia and splanchnic hypervolemia. Thoracic hypovolemia and splanchnic hypervolemia characterize certain patients with postural tachycardia syndrome (POTS) during orthostatic stress. These patients also experience abnormal phase II hypotension and phase IV hyperte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 289 1 شماره
صفحات -
تاریخ انتشار 2005