Resolution of an intense sweetener mixture by use of a flow injection sensor with on-line solid-phase extraction. Application to saccharin and aspartame in sweets and drinks.

نویسندگان

  • L F Capitán-Vallvey
  • M C Valencia
  • E Arana Nicolás
  • J F García-Jiménez
چکیده

An integrated solid-phase spectrophotometry-FIA method is proposed for simultaneous determination of the mixture of saccharin (1,2-benzisothiazol-3(2H)-one-1,1-dioxide; E-954) (SA) and aspartame (N-L-alpha-aspartyl-L-phenylalanine-1-methyl ester; E-951) (AS). The procedure is based on on-line preconcentration of AS on a C18 silica gel minicolumn and separation from SA, followed by measurement, at lambda = 210 nm, of the absorbance of SA which is transiently retained on the adsorbent Sephadex G-25 placed in the flow-through cell of a monochannel FIA setup using pH 3.0 orthophosphoric acid-dihydrogen phosphate buffer, 3.75x10(-3) mol L(-1), as carrier. Subsequent desorption of AS with methanol enables its determination at lambda = 205 nm. With a sampling frequency of 10 h(-1), the applicable concentration range, the detection limit, and the relative standard deviation were from 1.0 to 200.0 microg mL(-1), 0.30 microg mL(-1), and 1.0% (80 microg mL(-1), n = 10), respectively, for SA and from 10.0 to 200.0 microg mL(-1), 1.4 microg mL(-1), and 1.6% (100 microg mL(-1), n = 10) for AS. The method was used to determine the amounts of aspartame and saccharin in sweets and drinks. Recovery was always between 99 and 101%. The method enabled satisfactory determination of blends of SA and AS in low-calorie and dietary products and the results were compared with those from an HPLC reference method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do sweetening agents interact with morphine-induced analgesia in the formalin test in mice?

  There is evidence that sweeteners such as sucrose and saccharin interact with endogenous opioid systems. Further research has shown that feeding different concentrations of sucrose and saccharin alter latency in the tail-flick test. In this study, the influence of a 12-day regimen of different sweetening agents, sucrose (32%), saccharin (0.08%) and aspartame (0.16%) on morphine-induced analge...

متن کامل

Flow-through spectrophotometric sensor for the determination of aspartame in low-calorie and dietary products.

A very simple flow-through sensor is presented for the determination of the intense sweetener aspartame in low-calorie and dietary products. The sensor is implemented in a monochannel flow-injection system with UV spectrophotometric detection using a Sephadex CM-C25 cationic exchanger packed 20 mm high in a flow cell. This method is based on the transient retention of a cationic species of the ...

متن کامل

The Effects of Pressure Difference in Nozzle’s two Phase Flow on the Quality of Exhaust Mixture

In the most application of nozzle with gas-liquid two-phase flow, the quality of mixture in exhaust of nozzle is the most important parameter as well as the flow velocity. On the other hand, in some industrial application, such as water injection in forced induction (turbocharged or supercharged) internal combustion engine the spray quality is the main goal of designing. In this case and for im...

متن کامل

Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination

The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...

متن کامل

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 385 2  شماره 

صفحات  -

تاریخ انتشار 2006