Measurement error of visual field tests in glaucoma.

نویسندگان

  • P G D Spry
  • C A Johnson
  • A M McKendrick
  • A Turpin
چکیده

AIM Psychophysical strategies designed for clinical visual field testing produce rapid estimates of threshold with relatively few stimulus presentations and so represent a trade-off between test quality and efficiency. The aim of this study was to determine the measurement error of a staircase algorithm similar to full threshold with standard automated perimetry (SAP) and frequency doubling perimetry (FDP) in glaucoma patients. METHODS Seven patients with early open angle glaucoma (OAG) were prospectively recruited. All were experienced in laboratory based psychophysics. Three matched test locations were examined with SAP (externally driven Humphrey field analyser) and FDP (CRT) in a single arbitrarily selected eye of each subject. Each location was tested twice with a 4-2-2 dB staircase strategy, similar to full threshold, and then with the method of constant stimuli (MOCS). Accuracy (threshold estimation error) was quantified by determination of differences between "true" threshold measurements made by MOCS and single staircase threshold estimates. Precision (repeatability) was quantified by the differences between repeated staircase threshold estimates. RESULTS Precision was relatively high for both tests, although higher for FDP than SAP at depressed sensitivity levels. The staircase strategy significantly underestimated threshold sensitivity for both test types, with the mean difference (95% CI) between staircase and MOCS thresholds being 4.48 dB (2.35 to 7.32) and 1.35 dB (0.56 to 1.73) for SAP and FDP respectively. Agreement levels (weighted kappa) between MOCS and staircase thresholds were found to be 0.48 for SAP and 0.85 for FDP. Although this "bias" appeared constant for FDP across all sensitivity levels, this was not the case for SAP where accuracy decreased at lower sensitivity levels. CONCLUSION Estimations of threshold sensitivity made using staircase strategies common to clinical visual field test instrumentation are associated with varying degrees of measurement error according to visual field test type and sensitivity. In particular, SAP significantly overestimates the "true" level of sensitivity, particularly in damaged areas of the visual field, suggesting that clinical data of this type should be interpreted with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

What is the Real Cause of Glaucoma?

Introduction: The term glaucoma refers to a group of diseases that have a characteristic optic neuropathy with associated visual field loss in common. Intraocular pressure has been considered to be the only causal factor for glaucoma and the only factor that can be manipulated to alter the course of the disease. But considering high intraocular pressure as the only factor responsible for glauco...

متن کامل

The Relationship Between Visual Acuity and the Reproducibility of Visual Field Measurements in Glaucoma Patients.

PURPOSE The purpose of this study was to investigate the association between visual acuity (VA) and reproducibility of test-retest visual field (VF) measurements in glaucoma patients. METHODS Subjects were comprised of 627 eyes of 627 open-angle glaucoma patients. The reproducibility of two Humphrey VFs (24-2 or 30-2 Swedish Interactive Threshold Algorithm tests) examined twice within the per...

متن کامل

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Repeatability of the Glaucoma Hemifield Test in automated perimetry.

PURPOSE To examine the concordance of the Glaucoma Hemifield Test and other global visual field indexes between two consecutive automated visual field tests. METHODS Normal subjects, subjects with ocular hypertension, and subjects with glaucoma had two automated visual field tests on the Humphrey Field Analyzer. The Glaucoma Hemifield Test results, mean deviation, and corrected pattern standa...

متن کامل

Depression and Quality of Life in Patients with Glaucoma

Purpose: To investigate the frequency of depression and quality of life in patients with glaucoma. Methods: This cross-sectional study included 204 patients (102 males and 102 females) with a mean age of 58.9±11.96 and a range of 40 to 85 years old. Achromatic perimetry was performed, using the HFA SITA-standard 24-2. Severity was stratified according to the Nelson Glaucoma Severity Scale (base...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 87 1  شماره 

صفحات  -

تاریخ انتشار 2003