Automated On-line Preconcentration System for Electrothermal Atomic Absorption Spectrometry for the Determination of Copper and Molybdenum in Sea-water

نویسندگان

  • YU-HSIANG SUNG
  • SHANG-DA HUANG
چکیده

absorption spectrometry was developed. The performance of retain transition metal ions. After the sample loading step, the the on-line preconcentration system was tested by determining metal ions are stripped from the column with a suitable eluent Cu and Mo in sea-water. Calibration graphs constructed from and directly injected into the nebulizer of a flame atomic the preconcentration of standards in 0.2% 3 solution were absorption or a plasma emission spectrometer for detection. used. On-line preconcentration is computer-controlled. A On-line preconcentration systems are better than o -line batch miniature Muromac A-1 resin column was inserted at the tip preconcentration methods, because the former are more of the AS-60 autosampler arm. A modification of the AS-60 e cient, reproducible, easily automated, have low consumption autosampler in the tubing line and circuit allowed either flow of sample and reagent and low risk of contamination.18On-line of the sample through the column or operation of the flow injection column preconcentration in atomic spectrometry autosampler in the normal mode. Retention of the metal ions was reviewed by Fang et al.19 The on-line column preconcenas complexes on the microcolumn was achieved by using tration systems with liquid delivery forced by air o er a Muromac A-1 as the chelating resin; 20% v/v 3 was then number of advantages:20–22 ease of automation; lower conused for elution. With a 198.6 ml sample loop, the throughput sumption of reagent; reduced risk of contamination; and the is 14 samples h−1. Detection limits are 0.009 mg l−1 for Cu peristaltic pump can be used as the air drive. Beinrohr et al.20 (606.9 ml sample loop) and 0.06 mg l−1 for Mo (50 ml sample were the first to introduce air transportation of sample/eluent loop and repeated four times). The accuracy of the method streams obtained from the air support of the atomic absorption was confirmed by the analysis of certified reference saline spectrometer. Azeredo et al.21 introduced the peristaltic pump waters. as the air drive and integrated column preconcentration with

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Utilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples

In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...

متن کامل

Application of Ion - Imprinted Polymer Synthesized as New Sorbent for Preconcentration and Separation of Thallium (I) and Its Determination by Electrothermal Atomic Absorption Spectroscopy

At this study, thallium (I) ion-imprinted polymer, as a novel sorbent for Tl (I) and comparison with Tl(III) ion-imprinted polymer has been synthesized. This sorbent for preconcentration and solid-phase extraction of Tl(I) ions from aqueous solutions, used. Through preparing the binary complex of Tl(I) ions with 5, 7-dichloroquinoline-8-ol (DCQ) the particles of thallium (I) Ion-Imprinted P...

متن کامل

Preconcentration and Determination of Lead for Trace Levels in Water and Wastewater Samples by Vortex-Assisted Microextraction Using TPAS as a New Synthetic Complexing Agent with Electrothermal Atomic Absorption Spectroscopy Detection

A simple and rapid solidified vortex assisted 1-undecanol based liquid-liquid microextraction technique was proposed for preconcentration of trace levels of lead ions. The extraction solvent (1-undecanol) was dispersed into the aqueous samples by the assistance of vortex agitator. 100 µL of 1-undecanol containing ethyl (2Z)-3-[(5-chloro-7-methyl[1,3]thiazolo[5,4-d]pyrimidi...

متن کامل

Dispersive Liquid-liquid Microextraction Based on Solidification of Floating Organic Drop for Simultaneous Separation/preconcentration of Nickel, Cobalt and Copper Prior to Determination by Electrothermal Atomic Absorption Spectrometry

A dispersive liquid–liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 μL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997