In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.

نویسندگان

  • Reza Motaghiannezam
  • Daniel M Schwartz
  • Scott E Fraser
چکیده

PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3D images with scanning angles up to ∼70° × 35°. The similar features were observed in the choroidal layers by imaging three healthy volunteers. En face images, extracted at different depths, capture features of the retinal and choroidal vasculature networks and substructure. Retinal and choroidal thicknesses were measured over scanning angles of ∼14° × 14°, yielding retinal and choroidal thickness maps. RESULTS The retinal layers, choriocapillaris (CC), Sattler's layer (SL), Haller's layer (HL), and the lamina suprachoroid layer (LSL) were delineated in 2D sagittal tomograms. The sagittal tomograms and en face reflectance images over a 2-cm(2) field of view captured the paraoptic, lateral and medial distal short posterior ciliary artery (SPCA) branches as well as the two lateral and medial long posterior ciliary arteries (LPCAs). En face images in the HL revealed the superotemporal, inferotemporal, superonasal, and inferonasal major choroidal vessels. CONCLUSIONS High-speed, high-resolution SS-OCT centered at 1060 nm enables retinal and choroidal vasculature networks visualization, including retina vessels, posterior ciliary artery (PCA) branches, and venous vascular patterns. This technology offers diagnostic opportunities by monitoring change in these networks, substructure, and retinal and choroidal thicknesses during disease initiation and progression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential phase-contrast, swept-source optical coherence tomography at 1060 nm for in vivo human retinal and choroidal vasculature visualization.

Human retinal and choroidal vasculature was visualized by a differential phase-contrast (DPC) method using high-speed, swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was recognized as regions of motion by creating differential phase-variance (DPV) tomograms: multiple B-scans of individual slices through the retina were collected and the variance of the phase diff...

متن کامل

In vivo human retinal and choroidal vasculature visualization using differential phase contrast swept source optical coherence tomography at 1060 nm

A differential phase contrast (DPC) method is validated for in vivo human retinal and choroidal vasculature visualization using high-speed swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was identified as regions of motion by creating differential phase variance (DPV) tomograms: multiple B-scans were collected of individual slices through the retina and the varian...

متن کامل

Imaging limbal and scleral vasculature using Swept Source Optical Coherence Tomography.

We demonstrate an application of high-speed swept source optical coherence tomography for vessel visualization in the anterior segment of the human eye. The human corneo-scleral junction and sclera was imaged in vivo. Imaging was performed using a swept source OCT system operating at the 1050nm wavelength range and 100kHz A-scan rate. High imaging speed enables the generation of 3D depth-resolv...

متن کامل

Ultrahigh-speed non-invasive widefield angiography.

Retinal and choroidal vascular imaging is an important diagnostic benefit for ocular diseases such as age-related macular degeneration. The current gold standard for vessel visualization is fluorescence angiography. We present a potential non-invasive alternative to image blood vessels based on functional Fourier domain optical coherence tomography (OCT). For OCT to compete with the field of vi...

متن کامل

Logarithmic intensity and speckle-based motion contrast methods for human retinal vasculature visualization using swept source optical coherence tomography

We formulate a theory to show that the statistics of OCT signal amplitude and intensity are highly dependent on the sample reflectivity strength, motion, and noise power. Our theoretical and experimental results depict the lack of speckle amplitude and intensity contrasts to differentiate regions of motion from static areas. Two logarithmic intensity-based contrasts, logarithmic intensity varia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2012