Evaluation of large aberrations using a lateral-shear interferometer having variable shear.
نویسندگان
چکیده
A variable shear lateral shearing interferometer consisting of two holographically produced crossed diffraction gratings is used to test nonrotationally symmetric wavefronts having aberrations greater than 100 wavelengths and slope variations of more than 400 wavelengths/diameter. Comparisons are made with results of Twyman-Green interferometric tests for wavefront aberrations of up to thirty wavelengths. The results indicate that small wavefront aberrations can be measured as accurately with the lateral-shear interferometer as with the Twyman-Green interferometer and that aberrations that cannot be measured at all with a Twyman-Green interferometer can be measured to about 1% accuracy or better.
منابع مشابه
Double Grating Interferometer with Variable Lateral Shear
A modified Ronchi interferometer using two identical gratings is described. This instrument is very suitable for the measurement of small, zonal aberrations, since the shear can be changed continuously by rotating one grating with respect to the other, while the direction and magnitude of the tilt between the sheared wavefronts can be varied by adjusting the distances of the two gratings from t...
متن کاملDouble frequency grating lateral shear interferometer.
A simple grating lateral shear interferometer is described that can be made to give simultaneously two interferograms having shear in two orthogonal directions. The shear for the two orthogonal directions is produced in one plane by one double frequency crossed diffraction grating that can easily be produced holographically. Translating the grating sideways causes the irradiance of the interfer...
متن کاملUse of an ac heterodyne lateral shear interferometer with real-time wavefront correction systems.
An analysis is performed to determine the accuracy with which an ac heterodyne lateral shear interferometer can measure wavefront aberrations if a white light extended source is used with the interferometer, and shot noise is the predominate noise source. The analysis shows that for uniform circular or square sources larger than a derived minimum size, the wavefront measurement accuracy depends...
متن کاملInterferometer for measuring power distribution of ophthalmic lenses.
The use of a lateral shear interferometer in measuring the power variation of ophthalmic lenses is described and demonstrated. It is shown that an appropriate lateral shear interferometer directly measures the power variation of an ophthalmic lens. If the ophthalmic lens has a toric surface, the power for each axis can be measured separately. Individual surfaces can be tested, as well as the wh...
متن کاملبررسی تأثیر محصورشدگی بتن در رفتار غیرخطی دیوارهای برشی بتنآرمه بالدار
Flanged shear walls are used extensively in moderate- and high-rise buildings to resist lateral loads induced by earthquakes. The seismic performance of many buildings is, therefore, closely linked to the behavior of the reinforced concrete walls. They must be carefully designed to provide not only adequate strength, but also sufficient ductility to avoid brittle failure under strong lateral lo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 14 1 شماره
صفحات -
تاریخ انتشار 1975