In vivo application of an optical segment tracking approach for bone loading regimes recording in humans: a reliability study.

نویسندگان

  • Peng-Fei Yang
  • Maximilian Sanno
  • Bergita Ganse
  • Timmo Koy
  • Gert-Peter Brüggemann
  • Lars Peter Müller
  • Jörn Rittweger
چکیده

This paper demonstrates an optical segment tracking (OST) approach for assessing the in vivo bone loading regimes in humans. The relative movement between retro-reflective marker clusters affixed to the tibia cortex by bone screws was tracked and expressed as tibia loading regimes in terms of segment deformation. Stable in vivo fixation of bone screws was tested by assessing the resonance frequency of the screw-marker structure and the relative marker position changes after hopping and jumping. Tibia deformation was recorded during squatting exercises to demonstrate the reliability of the OST approach. Results indicated that the resonance frequencies remain unchanged prior to and after all exercises. The changes of Cardan angle between marker clusters induced by the exercises were rather minor, maximally 0.06°. The reproducibility of the deformation angles during squatting remained small (0.04°/m-0.65°/m). Most importantly, all surgical and testing procedures were well tolerated. The OST method promises to bring more insights of the mechanical loading acting on bone than in the past.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tibia segment deformation in response to simulated muscle forces: a cadaveric study with a novel optical segment tracking (OST) approach.

OBJECTIVES A novel optical segment tracking (OST) approach reliant upon motion capturing was previously proposed to assess human tibia segment deformation. The purposes of the present study were to validate the OST approach and assess the contribution of muscular forces to the bone deformation in a well-defined ex vivo human model. METHODS A custom-made Lower Extremity Loading Device (LELD) w...

متن کامل

Torsion and Antero-Posterior Bending in the In Vivo Human Tibia Loading Regimes during Walking and Running

Bending, in addition to compression, is recognized to be a common loading pattern in long bones in animals. However, due to the technical difficulty of measuring bone deformation in humans, our current understanding of bone loading patterns in humans is very limited. In the present study, we hypothesized that bending and torsion are important loading regimes in the human tibia. In vivo tibia se...

متن کامل

The Validity and Interrater Reliability of Video-Based Posture Observation During Asymmetric Lifting Tasks

OBJECTIVE The objective was to evaluate the validity and interrater reliability of a video-based posture observation method for the major body segment angles during asymmetric lifting tasks. BACKGROUND Observational methods have been widely used as an awkward-posture assessment tool for ergonomics studies. Previous research proposed a video-based posture observation method with estimation of ...

متن کامل

In vivo measurements of human bone deformation using optical segment tracking: surgical approach and validation in a three-point bending test.

The purpose of the study was to validate optical segment tracking, a new method for in vivo human tibia deformation measurements and to assess bending in a three-point bending test. The approach relies upon optical motion capturing of reflecting marker clusters affixed to the bone via screws inserted three millimeters into the corticalis in local anesthesia. The method was tested in five health...

متن کامل

Second Order Sliding Mode Observer-Based Control for Uncertain Nonlinear MEMS Optical Switch

This paper studies theuncertain nonlinear dynamics of a MEMS optical switch addressing electrical, mechanical and optical subsystems. Recently, MEMS optical switch has had significant merits in reliability, control voltage requirements and power consumption. However, an inherent weakness in designing control for such systems is unavailability of switch position information at all times due to t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2014