Quality assurance in mammography: College of Radiology Survey in Malaysia.

نویسندگان

  • E L M Ho
  • K H Ng
  • J H D Wong
  • H B Wang
چکیده

Malaysia's mammography QA practice was surveyed based on the Malaysian Ministry of Health and the American College of Radiology (ACR) requirements. Data on mammography unit, processor, image receptor, exposure factors, mean glandular dose (MGD), sensitometry, image quality and viewbox luminance were obtained. Mean developer temperature and cycle time were 34.1 +/- 1.8degreesC and 107.7 +/- 33.2 seconds. Mean base+fog level, speed index and contrast index were 0.20+/-0.01, 1.20+/-0.01 and 1.33+/-0.26 respectively. Eighty-six percent of the fifty centres passed the image quality test while 12.5% complied with ACR recommended viewbox luminance. Average MGD was 1.0+/-0.4 mGy. Malaysia is on the right track for QA but with room for total quality improvement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quality assurance for grey-scale imaging.

In 1992, the American College of Radiology (ACR) recommended a specific phantom and image analysis procedure for (x-ray) mammography (American College of Radiology 1992). This event removed uncertainty in the USA regarding quality assurance (QA) in mammography. Although the phantom and analysis procedure are probably not ideal, existence of definitive recommendations has resulted in essentially...

متن کامل

The American College of Radiology Mammography Accreditation Program.

This article discusses the background, goals, criteria, current results, impact, and future directions of the American College of Radiology's (ACR's) Mammography Accreditation Program. To date, approximately one half of the mammographic units in the United States have voluntarily applied for accreditation through the ACR program, with approximately one quarter of the units in the United States ...

متن کامل

Quality assurance for screening mammography: an international comparison.

STUDY OBJECTIVE In 1998, the International Breast Cancer Screening Network (IBSN) sponsored an assessment of quality assurance policies and practices to define their scope for population-based screening mammography programmes across IBSN countries. DESIGN Analysis of data from a survey designed to assess multiple elements of screening programme quality assurance, including organisation of qua...

متن کامل

Assessment of mammography quality in Istanbul.

PURPOSE We aimed to evaluate the mammography image quality in İstanbul and to survey the awareness of mammography quality. MATERIALS AND METHODS Fifty-five mammography units in İstanbul were visited. The mammography image quality was evaluated using a standard American College of Radiology (ACR) accreditation phantom. The phantom contained 16 objects, and a score of at least 10 of 16 was acce...

متن کامل

Quality assurance and quality control in mammography: a review of available guidance worldwide

OBJECTIVES Review available guidance for quality assurance (QA) in mammography and discuss its contribution to harmonise practices worldwide. METHODS Literature search was performed on different sources to identify guidance documents for QA in mammography available worldwide in international bodies, healthcare providers, professional/scientific associations. The guidance documents identified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 61 2  شماره 

صفحات  -

تاریخ انتشار 2006