Second order total generalized variation (TGV) for MRI.
نویسندگان
چکیده
Total variation was recently introduced in many different magnetic resonance imaging applications. The assumption of total variation is that images consist of areas, which are piecewise constant. However, in many practical magnetic resonance imaging situations, this assumption is not valid due to the inhomogeneities of the exciting B1 field and the receive coils. This work introduces the new concept of total generalized variation for magnetic resonance imaging, a new mathematical framework, which is a generalization of the total variation theory and which eliminates these restrictions. Two important applications are considered in this article, image denoising and image reconstruction from undersampled radial data sets with multiple coils. Apart from simulations, experimental results from in vivo measurements are presented where total generalized variation yielded improved image quality over conventional total variation in all cases.
منابع مشابه
Inverse Problems with Second-order Total Generalized Variation Constraints
Total Generalized Variation (TGV) has recently been introduced as penalty functional for modelling images with edges as well as smooth variations [2]. It can be interpreted as a “sparse” penalization of optimal balancing from the first up to the kth distributional derivative and leads to desirable results when applied to image denoising, i.e., L-fitting with TGV penalty. The present paper studi...
متن کاملTotal Generalized Variation (TGV) for MRI
Fig. 3: TGV2 Image reconstruction of undersampled radial data with 48, 32 and 24 spokes. Conventional NUFFT reconstruction (left), TV (middle) and TGV2 (right). Fig. 4: Magnified views from Fig. 3. Conventional NUFFT reconstruction (left), TV (middle) and TGV2 (right). Fig. 1: Illustration of TV (middle) and TGV2 (right) denoising of a numerical ramp image. Total Generalized Variation (TGV) for...
متن کاملQuantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast
PURPOSE Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI o...
متن کاملProperties of L-TGV: The one-dimensional case
We study properties of solutions to second order Total Generalized Variation (TGV) regularized L1-fitting problems in dimension one. Special attention is paid to the analysis of the structure of the solutions, their regularity and the effect of the regularization parameters. 31 March 2011 /Updated: 14 September 2012
متن کاملSecond-order TGV model for Poisson noise image restoration
Restoring Poissonian noise images have drawn a lot of attention in recent years. There are many regularization methods to solve this problem and one of the most famous methods is the total variation model. In this paper, by adding a quadratic regularization on TGV regularization part, a new image restoration model is proposed based on second-order total generalized variation regularization. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 65 2 شماره
صفحات -
تاریخ انتشار 2011