Comparison of technetium Tc 99m hexamethylpropyleneamine oxime single-photon emission tomograph with stump pressure during the balloon occlusion test of the internal carotid artery.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Measuring blood pressure (stump pressure) in the distal internal carotid artery during occlusion of the internal carotid artery is reportedly a reliable safety index with which to predict ischemia following permanent occlusion of the internal carotid artery. We compared the stump pressure during occlusion of the internal carotid artery with single-photon emission CT (SPECT) using technetium Tc 99m hexamethylpropyleneamine oxime (HMPAO). METHODS Twenty-seven patients underwent the balloon occlusion test. After occlusion of the internal carotid artery was performed by a balloon catheter, technetium Tc 99m HMPAO was injected, and then the balloon remained inflated for 15 minutes. The stump pressure was continuously monitored for those 15 minutes. After the balloon catheter was deflated and removed, SPECT was performed. Sixty-four symmetric pairs of regions of interest were set on both sides of the cerebral hemisphere. The radioactivity count ratio (L/n ratio) of the occluded side to the contralateral normal side was calculated. We defined hypoperfusion as an area with an L/n ratio <0.8. The minimum mean stump pressure (minMSP) during the balloon occlusion test and the pressure ratio of the minMSP to the mean systemic pressure were compared with the hypoperfusion area on SPECT. RESULTS The number of regions of interest with hypoperfusion was significantly (P < .001) greater in patients with a minMSP <40 mm Hg (mean [+/-SD] = 31.5 +/- 13.7) than in patients with a minMSP > or =40 mm Hg (5.1 +/- 4.0). The number of regions of interest with hypoperfusion was also significantly (P < .001) greater in patients with a pressure ratio <0.5 (26.7 +/- 15.8) than in patients with a pressure ratio > or =0.5 (4.5 +/- 3.5). CONCLUSION The minMSP during the balloon test occlusion reflects the extent of the hypoperfused area measured by SPECT using technetium Tc 99m HMPAO.
منابع مشابه
Assessing adequacy of collateral circulation during balloon test occlusion of the internal carotid artery with 99mTc-HMPAO SPECT.
A balloon test occlusion of the internal carotid artery was performed in 11 patients with internal carotid artery aneurysms. Tolerance by patients was assessed by a combination of clinical examination; angiography; electroencephalography; 99mTc-hexamethylpropyleneamine oxime (99mTc-HMPAO) single-photon emission computed tomography (SPECT) with relative quantification; and, in four patients, 99m...
متن کاملImproved detection of cerebral hypoperfusion with internal carotid balloon test occlusion and 99mTc-HMPAO cerebral perfusion SPECT imaging.
A new method that employs a cerebral perfusion imaging agent, 99mTc-HMPAO, is described for identifying those patients who clinically pass an internal carotid artery balloon test occlusion but who then may develop a cerebral infarction after permanent occlusion. Test balloon occlusion of the internal carotid artery was performed in 17 patients, and 99mTc-HMPAO was injected intravenously while t...
متن کاملEvaluation of ""Tc-Hexamethylpropyleneamine Oxime Cerebral Blood Flow Mapping After Acute Focal Ischemia in Rats
Although the blood flow tracer hexamethylpropyleneamine oxime is now widely used for cerebral blood flow mapping using single-photon emission computed tomography, its uptake into acutely ischemic brain has not been well studied. We performed a double-label autoradiographic study in which "Tc-hexamethylpropyleneamine oxime uptake was compared with [C]iodoantipyrine-derived cerebral blood flow 0....
متن کاملDiagnostic applications of simultaneously acquired dual-isotope single-photon emission CT scans.
PURPOSE To report the development and validation of a technique of dual tracer single-photon emission CT brain imaging using technetium-99m hexamethylpropyleneamine oxime and iodine-123 iodoamphetamine agents and the application of this technique in patients with a variety of diagnoses. METHODS Contamination between the two isotopes' energy windows was calculated by opening both energy window...
متن کاملA comparative study of perfusion CT and 99mTc-HMPAO SPECT measurement to assess cerebrovascular reserve capacity in patients with internal carotid artery occlusion
BACKGROUND AND PURPOSE Patients with internal carotid artery (ICA) occlusion can demonstrate impaired cerebral vascular reserve (CVR). The detection of CVR using single photon emission CT (SPECT) is nowadays widely accepted as a predictor in the diagnostic pathway in patients considered for cerebral revascularization. Recently perfusion CT (PCT) gained widely acceptance in stroke imaging. The p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2005