Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
نویسندگان
چکیده
There is the need for a clinical assay to determine the extent to which a patient's blood is effectively anticoagulated by the low-molecular-weight-heparin (LMWH), enoxaparin. There are also urgent clinical situations where it would be important if this could be determined rapidly. The present assay is designed to accomplish this. We only assayed human blood samples that were spiked with known concentrations of enoxaparin. The essential feature of the present assay is the quantification of the efficacy of enoxaparin in a patient's blood sample by degrading it to complete inactivity with heparinase. Two blood samples were drawn into Vacutainer tubes (Becton-Dickenson; Franklin Lakes, NJ) that were spiked with enoxaparin; one sample was digested with heparinase for 5 min at 37 °C, the other sample represented the patient's baseline anticoagulated status. The percent shortening of clotting time in the heparinase-treated sample, as compared to the baseline state, yielded the anticoagulant contribution of enoxaparin. We used the portable, battery operated Hemochron 801 apparatus for measurements of clotting times (International Technidyne Corp., Edison, NJ). The apparatus has 2 thermostatically controlled (37 °C) assay tube wells. We conducted the assays in two types of assay cartridges that are available from the manufacturer of the instrument. One cartridge was modified to increase its sensitivity. We removed the kaolin from the FTK-ACT cartridge by extensive rinsing with distilled water, leaving only the glass surface of the tube, and perhaps the detection magnet, as activators. We called this our minimally activated assay (MAA). The use of a minimally activated assay has been studied by us and others. (2-4) The second cartridge that was studied was an activated partial thromboplastin time (aPTT) assay (A104). This was used as supplied from the manufacturer. The thermostated wells of the instrument were used for both the heparinase digestion and coagulation assays. The assay can be completed within 10 min. The MAA assay showed robust changes in clotting time after heparinase digestion of enoxaparin over a typical clinical concentration range. At 0.2 anti-Xa I.U. of enoxaparin per ml of blood sample, heparinase digestion caused an average decrease of 9.8% (20.4 sec) in clotting time; at 1.0 I.U. per ml of enoxaparin there was a 41.4% decrease (148.8 sec). This report only presents the experimental application of the assay; its value in a clinical setting must still be established.
منابع مشابه
A microfluidic anti-Factor Xa assay device for point of care monitoring of anticoagulation therapy.
The development of new point of care coagulation assay devices is necessary due to the increasing number of patients requiring long-term anticoagulation in addition to the desire for appropriate, targeted anticoagulant therapy and a more rapid response to optimization of treatment. The majority of point of care devices currently available for hemostasis testing rely on clot-based endpoints whic...
متن کاملAnticoagulant properties of enoxaparin 400 IU/mL–40 % ethanol catheter lock solution
Unfractionated heparin (UFH) is the most widely used interdialytic lock solution but has no anti-infectious properties. Ethanol at a content ≥40 %v/v eradicates experimental biofilm but has no anticoagulant properties. In contrast to UFH, enoxaparin (Enox) can be combined with 40 % ethanol without precipitation. Enoxaparin 400 UI/mL-40 % ethanol (Enox/Eth) has antibiofilm properties and therefo...
متن کاملEffect of unfractionated heparin and a low molecular weight heparin (enoxaparin) on coagulant activity of cultured human endothelial cells.
BACKGROUND AND OBJECTIVES Unfractionated heparin and low molecular weight heparins exert their anticoagulant effect by mobilizing tissue factor pathway inhibitor (TFPI) from the vascular endothelium into the blood circulation. We compared the influence of unfractionated heparin and enoxaparin on the anticoagulant function of cultured human endothelial cells. DESIGN AND METHODS Monolayers of h...
متن کاملBemiparin versus Enoxaparin in the Prevention of Venous Thromboembolism among Intensive Care Unit Patients
BACKGROUND Critically ill patients are considered a high-risk group for developing venous thromboembolism (VTE). Due to their impaired cardiopulmonary reserve, these VTEs may result in significant morbidity and mortality. In this study, we compared two types of low molecular weight heparin, enoxaparin, and bemiparin, as regards to their efficacy and safety in VTE prevention among Intensive Care...
متن کاملEffects of Enoxaparin Emulsion on Dimethylbenzanthracene-induced Breast Cancer in Female Rats
Background : Enoxaparin is an anticoagulant medication. Anticoagulation inhibits tumor cell–mediated release of angiogenic proteins and diminishes angiogenic response. Angiogenesis is an important event in various cancers such as breast cancer. Angiogenesis provide oxygen and nutrients to tumor cells and causes tumor progression. The aim of the present study was to evaluate the anti-angio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 32 شماره
صفحات -
تاریخ انتشار 2012