A Portable Impedance Immunosensing System for Rapid Detection of Salmonella Typhimurium
نویسندگان
چکیده
SalmonellaTyphimurium is one of the most dangerous foodborne pathogens and poses a significant threat to human health. The objective of this study was to develop a portable impedance immunosensing system for rapid and sensitive detection of S. Typhimurium in poultry. The developed portable impedance immunosensing system consisted of a gold interdigitated array microelectrode (IDAM), a signal acquisitive interface and a laptop computer with LabVIEW software. The IDAM was first functionalized with 16-Mercaptohexadecanoic acid, and streptavidin was immobilized onto the electrode surface through covalent bonding. Then, biotin-labelled S. Typhimurium-antibody was immobilized onto the IDAM surface. Samples were dropped on the surface of the IDAM and the S. Typhimurium cells in the samples were captured by the antibody on the IDAM. This resulted in impedance changes that were measured and displayed with the LabVIEW software. An equivalent circuit of the immunosensor demonstrated that the largest change in impedance was due to the electron-transfer resistance. The equivalent circuit showed an increase of 35% for the electron-transfer resistance value compared to the negative control. The calibration result indicated that the portable impedance immunosensing system could be used to measure the standard impedance elements, and it had a maximum error of measurement of approximately 13%. For pure culture detection, the system had a linear relationship between the impedance change and the logarithmic value of S. Typhimurium cells ranging from 76 to 7.6 × 10⁶ CFU (colony-forming unit) (50 μL)-1. The immunosensor also had a correlation coefficient of 0.98, and a high specificity for detection of S. Typhimurium cells with a limit of detection (LOD) of 10² CFU (50 μL)-1. The detection time from the moment a sample was introduced to the display of the results was 1 h. To conclude, the portable impedance immunosensing system for detection of S. Typhimurium achieved an LOD that is comparable with commercial electrochemical impedance instruments. The developed impedance immunosensor has advantages in portability, low cost, rapid detection and label-free features showing a great potential for in-field detection of foodborne pathogens.
منابع مشابه
Interdigitated microelectrode (IME) impedance sensor for the detection of viable Salmonella typhimurium.
Interdigitated microelectrodes (IMEs) were used as impedance sensors for rapid detection of viable Salmonella typhimurium in a selective medium and milk samples. The impedance growth curves, impedance against bacterial growth time, were recorded at four frequencies (10Hz, 100Hz, 1kHz, and 10kHz) during the growth of S. typhimurium. The impedance did not change until the cell number reached 10(5...
متن کاملMolecular Characterization of a Salmonella Typhimurium Isolate from Caspian Pony
Typhoid disease or salmonellosis is a common sickness in horses. In several epidemiological studies inhospitalized horses, several serotypes of Salmonella often are predominant in nosocomial infections.Transportation, overcrowding, dehydration, oral antimicrobial therapy and infections are the risk factorswhich may activate latent or subclinical salmonellosis. In this study, t...
متن کاملSalmonella typhimurium in Natrix natrix: detection and identification by culture and multiplex PCR methods
A water snake (Natrix natrix) was referred to the Small Animal Teaching Hospital, Faculty of Veterinary Medicine, University of Tehran. It had two subcutaneous masses. Radiographic and ultrasonographic images revealed the presence of two subcutaneous abscesses. The abscesses were removed surgically and specimens were examined by conventional microbial culture and multiplex PCR. Inv-A universal ...
متن کاملEfficient and Rapid Detection of Salmonella Using Microfluidic Impedance Based Sensing
We present a low cost, easy to fabricate biosensor, which can quickly and accurately detect Salmonella typhimurium. This study also compares the advantages of the microfluidic biosensor over a nonmicrofluidic biosensor. High density interdigitated electrode array was used to detect Salmonella cells inside a microfluidic chip. Monoclonal anti-Salmonella antibodies were allowed to be immobilized ...
متن کاملA Highly Sensitive ELISA and Immunochromatographic Strip for the Detection of Salmonella typhimurium in Milk Samples
Murine monoclonal antibodies to target Salmonella typhimurium flagellin and lipopolysaccharide (LPS) were prepared and characterized. For the immunological detection of S. typhimurium, different pairs of monoclonal antibodies (MAbs) were tested in a sandwich enzyme linked immunosorbent assay (ELISA) format. After comparison, a sandwich ELISA and immunochromatographic strip based on LPS MAbs was...
متن کامل