Investigation of Characteristics at the Stem Cement Interface in Total Hip Replacement

نویسنده

  • H. Zhang
چکیده

The University Repository is a digital collection of the research output of the University, available on Open Access. Copyright and Moral Rights for the items on this site are retained by the individual author and/or other copyright owners. Users may access full items free of charge; copies of full text items generally can be reproduced, displayed or performed and given to third parties in any format or medium for personal research or study, educational or not-for-profit purposes without prior permission or charge, provided:

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical effects of stem cement interface characteristics in total hip replacement.

Stem cement debonding is 1 of the most common forms of fixation failure and is thought to be a prelude to gross loosening of a total hip reconstruction. However, the immediate consequences of debonding remains a matter of controversy. The dynamic effects of stem cement debonding in total hip reconstruction were analyzed using 3-dimensional finite element techniques. Stem cement interface condit...

متن کامل

Generation of Fretting Wear Debris at the Stem– Cement Interface in Total Hip Replacment

Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR). Those wear debris within a certain size range would transport along bone cement deficiencies to bone tissue, resulting in a significant bone resorption and subsequent aseptic loosening of the femoral component, which i...

متن کامل

Porosity reduction in bone cement at the cement-stem interface.

The fatigue failure of bone cement, leading to loosening of the stem, is likely to be one mode of failure of cemented total hip replacements. There is strong evidence that cracks in the cement are initiated at voids which act as stress risers, particularly at the cement-stem interface. The preferential formation of voids at this site results from shrinkage during polymerisation and the initiati...

متن کامل

Fixation of the Cemented Stem: Clinical Relevance of the Porosity and Thickness of the Cement Mantle

The aim of this review paper is to define the fixation of the cemented stem. Polymethyl methacrylate, otherwise known as "bone cement", has been used in the fixation of hip implants since the early 1960s. Sir John Charnley, the pioneer of modern hip replacement, incorporated the use of cement in the development of low frictional torque hip arthroplasty. In this paper, the concepts of femoral st...

متن کامل

Reproduction of fretting wear at the stem-cement interface in total hip replacement.

The stem-cement interface experiences fretting wear in vivo due to low-amplitude oscillatory micromotion under physiological loading, as a consequence it is considered to play an important part in the overall wear of cemented total hip replacement. Despite its potential significance, in-vitro simulation to reproduce fretting wear has seldom been attempted and even then with only limited success...

متن کامل

Femoral stem wear in cemented total hip replacement.

The great success of cemented total hip replacement to treat patients with endstage osteoarthritis and osteonecrosis has been well documented. However, its long-term survivorship has been compromised by progressive development of aseptic loosening, and few hip prostheses could survive beyond 25 years. Aseptic loosening is mainly attributed to bone resorption which is activated by an in-vivo mac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015