Evaluation of an air-abrasive device with amino acid glycine-powder during surgical treatment of peri-implantitis.

نویسندگان

  • Selena Toma
  • Jerome F Lasserre
  • Johana Taïeb
  • Michel C Brecx
چکیده

OBJECTIVE The aim of this retrospective study was to analyze collected data concerning the effect of an air-abrasive device (Perio-Flow®) during surgical treatment of peri-implantitis without addition of any antimicrobials. METHOD AND MATERIALS Data reports from 22 implants with peri-implantitis surgically treated using either an air-abrasive device (Perio- Flow) (test group), or plastic curettes and cotton pellets impregnated with saline (control group) were analyzed for the present study. Clinical and radiographic parameters plaque index (PI), gingival index (GI), probing pocket depth (PPD), and bone loss (BL) were previously assessed at baseline, 6 months, and 12 months after treatment. A repeated measures ANOVA test was used for each clinical and radiographic parameter (PI, GI, PPD, and BL). The implant and the patient were considered separately as the statistical unit. RESULTS Regarding betweengroup comparisons, PI scores remained low during the entire study period (at implant and patient levels). At the end of the study, GI and PPD reductions were statistically higher (P < .05) in the Perio-Flow group (implant level), and no differences were observed between the two groups at patient level (P > .05) (repeated measures ANOVA test). It was also noted that BL analyses (implant and patient levels) revealed no differences between baseline and 12 months in both groups. Nevertheless, only 8% from each treatment group were considered stabilized after 12 months. CONCLUSION Within the limitations of the present study, both groups (Perio-Flow and its control group) revealed a significant reduction of the clinical parameters. Moreover, the air-abrasive device group yielded better improvements regarding GI and PPD when the implant was considered as the statistical unit. However, if the stabilization of the disease was the final objective, these two treatments failed in resolving its activity. A longer follow-up and a larger number of patients would be needed to confirm these results and the benefit of adding this air-abrasive method of decontamination to the surgical procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Air powder abrasive treatment as an implant surface cleaning method: a literature review.

OBJECTIVE To evaluate the air powder abrasive treatment as an implant surface cleaning method for peri-implantitis based on the existing literature. MATERIALS AND METHODS A PubMed search was conducted to find articles that reported on air powder abrasive treatment as an implant surface cleaning method for peri-implantitis. The studies evaluated cleaning efficiency and surface change as a resu...

متن کامل

Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy

BACKGROUND An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. METHODS Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively...

متن کامل

Erythritol-Enriched Air-Polishing Powder for the Surgical Treatment of Peri-Implantitis

Peri-implantitis represents a major complication that can compromise the success and survival of implant-supported rehabilitations. Both surgical and nonsurgical treatment protocols were proposed to improve clinical parameters and to treat implants affected by peri-implantitis. A systematic review of the literature was performed on electronic databases. The use of air-polishing powder in surgic...

متن کامل

Titanium deposition after peri-implant care with the carbon dioxide laser.

PURPOSE Titanium endosseous implants are becoming increasingly important in dentistry because of their excellent long-term results. However, it has been reported that these implants may lead to higher concentrations of titanium, especially in the lungs and kidneys. The purpose of this study, therefore, was to determine whether CO2 laser-assisted decontamination of exposed implant surfaces is as...

متن کامل

Treatment of peri-implant mucositis using a glycine powder air-polishing or ultrasonic device: a randomized clinical trial.

AIM To evaluate the clinical treatment effects of a glycine powder air-polishing or ultrasonic device on peri-implant mucositis. MATERIALS AND METHODS Thirty-seven patients with one implant diagnosed with peri-implant mucositis (probing depth ≥4 mm (0.2N) and bleeding on probing (BOP) (primary outcome)) were randomly assigned to treatment with either glycine powder air-polishing (GPAP) or ult...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Quintessence international

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2014