A Comparison of Accuracy of Matrix Impression System with Putty Reline Technique and Multiple Mix Technique: An In Vitro Study

نویسندگان

  • M Praveen Kumar
  • Suneel G Patil
  • Bhandari Dheeraj
  • Keshav Reddy
  • Dinker Goel
  • Gopi Krishna
چکیده

BACKGROUND The difficulty in obtaining an acceptable impression increases exponentially as the number of abutments increases. Accuracy of the impression material and the use of a suitable impression technique are of utmost importance in the fabrication of a fixed partial denture. This study compared the accuracy of the matrix impression system with conventional putty reline and multiple mix technique for individual dies by comparing the inter-abutment distance in the casts obtained from the impressions. MATERIALS AND METHODS Three groups, 10 impressions each with three impression techniques (matrix impression system, putty reline technique and multiple mix technique) were made of a master die. Typodont teeth were embedded in a maxillary frasaco model base. The left first premolar was removed to create a three-unit fixed partial denture situation and the left canine and second premolar were prepared conservatively, and hatch marks were made on the abutment teeth. The final casts obtained from the impressions were examined under a profile projector and the inter-abutment distance was calculated for all the casts and compared. RESULTS The results from this study showed that in the mesiodistal dimensions the percentage deviation from master model in Group I was 0.1 and 0.2, in Group II was 0.9 and 0.3, and Group III was 1.6 and 1.5, respectively. In the labio-palatal dimensions the percentage deviation from master model in Group I was 0.01 and 0.4, Group II was 1.9 and 1.3, and Group III was 2.2 and 2.0, respectively. In the cervico-incisal dimensions the percentage deviation from the master model in Group I was 1.1 and 0.2, Group II was 3.9 and 1.7, and Group III was 1.9 and 3.0, respectively. In the inter-abutment dimension of dies, percentage deviation from master model in Group I was 0.1, Group II was 0.6, and Group III was 1.0. CONCLUSION The matrix impression system showed more accuracy of reproduction for individual dies when compared with putty reline technique and multiple mix technique in all the three directions, as well as the inter-abutment distance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Rewash on the Accuracy of Stone Dies Produced by Putty-Wash Technique

Background and Aims: An accurate impression of teeth and supporting structure is necessary to restore a lost tooth structure or to replace a tooth with crown and bridge. Although there are various methods for making impression, putty-wash technique is currently preferred since it is simple and does not require a special tray. Silicone elastomeric impression materials have suitable consistency f...

متن کامل

Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.

BACKGROUND Dimensional accuracy when making impressions is crucial to the quality of fixed prosthodontic treatment, and the impression technique is a critical factor affecting this accuracy. The purpose of this in vitro study was to compare the dimensional accuracy of the casts obtained from one step double mix, two step double mix polyvinyl siloxane putty- wash impression techniques using thre...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

Dimensional Accuracy of Polyvinyl Siloxane Impression Materials Considering Impression Techniques– A Literature Review

Objectives Impression accuracy is the main determinant of the fit, form and function of prosthetic restorations. Polyvinyl siloxane (PVS) is the material of choice in most clinical situations. The purpose of this paper is to provide an up-to-date review of scientific articles which discuss the dimensional accuracy of PVS impression material using various impression techniques, tray types and sp...

متن کامل

Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD

Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015