Effects of Breathing Pattern on Oxygen Delivery Via a Nasal or Pharyngeal Cannula.

نویسندگان

  • Natsuhiro Yamamoto
  • Tetsuya Miyashita
  • Shunsuke Takaki
  • Takahisa Goto
چکیده

BACKGROUND During sedation for upper gastrointestinal endoscopy, oxygen delivery via a nasal cannula is often necessary. However, the influences of the oxygen delivery route and breathing pattern on the F(IO2) have not been thoroughly investigated. The aim of this simulation study was to investigate the difference in the F(IO2) with a pharyngeal cannula versus nasal cannula during high- or low-tidal volume (V(T)) ventilation and open- or closed-mouth breathing. METHODS Six healthy volunteers were asked to breathe using 2 patterns of ventilation (high or low V(T)) via a sealed face mask connected to an endotracheal tube that was retrogradely inserted into the trachea of a mannequin. The mannequin also had a pharyngeal or nasal cannula inserted into the pharynx or attached to the nose, through which oxygen (2 or 5 L/min) was delivered. The mouth of the mannequin was kept open or closed by packing. We measured the F(IO2) of every breath for 1 min at each setting. RESULTS During low- and high-V(T) ventilation, the F(IO2) was highest at a flow of 5 L/min with a pharyngeal cannula. Oxygen delivery was higher with the pharyngeal cannula compared with the nasal cannula at all settings. Differences in flow did not result in significant differences in the F(IO2) with high- and low-V(T) ventilation. At a flow of 5 L/min via a pharyngeal cannula, open-mouth breathing resulted in a significantly higher F(IO2) compared with closed-mouth breathing. CONCLUSIONS A pharyngeal cannula provided a higher F(IO2) compared with a nasal cannula at the same oxygen flow. Open-mouth breathing resulted in a higher F(IO2) compared with closed-mouth breathing when 5 L/min oxygen was delivered via a pharyngeal cannula. The breathing pattern did not affect the F(IO2) in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung recruitment and breathing pattern during variable versus continuous flow nasal continuous positive airway pressure in premature infants: an evaluation of three devices.

OBJECTIVE To determine whether lung volume changes and breathing pattern parameters differ among 3 devices for delivery of nasal continuous positive airway pressure (CPAP) in premature infants. METHODS Thirty-two premature infants receiving nasal CPAP for apnea or mild respiratory distress were enrolled. Birth weight was (mean +/- standard deviation) 1081 +/- 316 g, gestational age 29 +/- 2 w...

متن کامل

Variability of inspired oxygen concentration with nasal cannulas.

BACKGROUND The likely values of inspired oxygen concentration (FIO2) of patients with chronic obstructive pulmonary disease breathing via nasal cannulas have not been assessed previously. METHODS Seven patients with chronic obstructive lung disease and seven healthy subjects were studied while breathing oxygen via nasal cannulas or fixed performance (Venturi) or uncontrolled (MC) oxygen masks...

متن کامل

A new pendant oxygen-conserving cannula which allows pursed lips breathing.

Multiple benefits of oxygen therapy for hypoxemic patients with chronic lung disease are well established. Steady flow oxygen therapy is inefficient, wasteful and has a high cost. The Oxymizer pendant improves efficiency of oxygen delivery compared with SF. However, the device requires that the patient inhale and exhale nasally to maximize its oxygen-saving properties. When patients do PLB they...

متن کامل

High-flow nasal cannula: recommendations for daily practice in pediatrics

High-flow nasal cannula (HFNC) is a relatively new device for respiratory support. In pediatrics, HFNC use continues to increase as the system is easily set up and is well tolerated by patients. The use of nasal cannula adapted to the infant's nares size to deliver heated and humidified gas at high flow rates has been associated with improvements in washout of nasopharyngeal dead space, lung mu...

متن کامل

Improvement of oxygen delivery in severe hypoxaemia by a reservoir cannula.

In 36 severely hypoxaemic patients (arterial oxygen tension (PaO2) less than 7.3 kPa or 55 mmHg), candidates for long-term oxygen therapy, we compared the effectiveness of three oxygen-delivery systems, the standard nasal prongs, a so-called oxygen-conserving reservoir device ("Oxymizer Pendant") and the reference pharyngeal catheter, at a preset flow rate of 2 l.min-1. After 30 min, the conser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 60 12  شماره 

صفحات  -

تاریخ انتشار 2015