Method Specific Calibration Corrects for DNA Extraction Method Effects on Relative Telomere Length Measurements by Quantitative PCR

نویسندگان

  • Luise A Seeker
  • Rebecca Holland
  • Sarah Underwood
  • Jennifer Fairlie
  • Androniki Psifidi
  • Joanna J Ilska
  • Ainsley Bagnall
  • Bruce Whitelaw
  • Mike Coffey
  • Georgios Banos
  • Daniel H Nussey
چکیده

Telomere length (TL) is increasingly being used as a biomarker in epidemiological, biomedical and ecological studies. A wide range of DNA extraction techniques have been used in telomere experiments and recent quantitative PCR (qPCR) based studies suggest that the choice of DNA extraction method may influence average relative TL (RTL) measurements. Such extraction method effects may limit the use of historically collected DNA samples extracted with different methods. However, if extraction method effects are systematic an extraction method specific (MS) calibrator might be able to correct for them, because systematic effects would influence the calibrator sample in the same way as all other samples. In the present study we tested whether leukocyte RTL in blood samples from Holstein Friesian cattle and Soay sheep measured by qPCR was influenced by DNA extraction method and whether MS calibration could account for any observed differences. We compared two silica membrane-based DNA extraction kits and a salting out method. All extraction methods were optimized to yield enough high quality DNA for TL measurement. In both species we found that silica membrane-based DNA extraction methods produced shorter RTL measurements than the non-membrane-based method when calibrated against an identical calibrator. However, these differences were not statistically detectable when a MS calibrator was used to calculate RTL. This approach produced RTL measurements that were highly correlated across extraction methods (r > 0.76) and had coefficients of variation lower than 10% across plates of identical samples extracted by different methods. Our results are consistent with previous findings that popular membrane-based DNA extraction methods may lead to shorter RTL measurements than non-membrane-based methods. However, we also demonstrate that these differences can be accounted for by using an extraction method-specific calibrator, offering researchers a simple means of accounting for differences in RTL measurements from samples extracted by different DNA extraction methods within a study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Sperm Telomere Length between Two Sperm Selection Procedures: Density Gradient Centrifugation and Zeta Potential

Background: Telomeres are particular sequences of DNA located at the end of the eukaryotic chromosomes that are essential for genome integrity. Telomere length in spermatozoa differs among males, as well as spermatozoa. Also, decreased telomere length in spermatozoa of infertile men is associated with the reduction of fertility potential and embryo quality. Density gradient centrifugation (DGC)...

متن کامل

Telomere length varies by DNA extraction method: implications for epidemiologic research--response.

We thank Hofmann and colleagues (1) for their report corroborating our discovery that the method used to extractDNA fromblood cells influences themeasurement of telomere length (2). Hoffman and colleagues found that peripheral leukocyte telomere lengthsmeasured by quantitative PCR were significantly longer in DNA that had been extracted by the ReliaPrep magnetic bead capture chemistry than in D...

متن کامل

Reliability and Short-Term Intra-Individual Variability of Telomere Length Measurement Using Monochrome Multiplexing Quantitative PCR

BACKGROUND Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period. METHODS AND FINDINGS Relative telomere length in peripheral blood was estimated usi...

متن کامل

Influence of DNA extraction methods on relative telomere length measurements and its impact on epidemiological studies

Measurement of telomere length is widely used in epidemiologic studies. Insufficient standardization of the measurements processes has, however, complicated the comparison of results between studies. We aimed to investigate whether DNA extraction methods have an influence on measured values of relative telomere length (RTL) and whether this has consequences for epidemiological studies. We perfo...

متن کامل

Telomere length measurement by a novel monochrome multiplex quantitative PCR method

The current quantitative polymerase chain reaction (QPCR) assay of telomere length measures telomere (T) signals in experimental DNA samples in one set of reaction wells, and single copy gene (S) signals in separate wells, in comparison to a reference DNA, to yield relative T/S ratios that are proportional to average telomere length. Multiplexing this assay is desirable, because variation in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016