We have investigated the mid-term outcome of total shoulder replacement using a keeled cemented glenoid component and a modern cementing technique with regard to the causes of failure and loosening of the components. Between 1997 and 2003 we performed 96 total shoulder replacements on 88 patients, 24 men and 64 women with a mean age of 69.7 years (31 to 82). The minimum follow-up was five years and at the time of review 87 shoulders (77 patients) were examined at a mean follow-up of 89.1 months (60 to 127). Cumulative survival curves were generated with re-operations (accomplished and planned), survivorship of the proshesis, loosening of the glenoid (defined as tilt > 5 degrees or subsidence > 5 mm), the presence of radiolucent lines and a Constant score of < 30 as the endpoints. There were two re-operations not involving revision of the implants and the survival rate of the prosthesis was 100.0% for the follow-up period, with an absolute Constant score of > 30 as the endpoint the survival rate was 98%. Radiological glenoid loosening was 9% after five years, and 33% after nine years. There was an incidence of 8% of radiolucent lines in more than three of six zones in the immediate post-operative period, of 37.0% after the first year which increased to 87.0% after nine years. There was no correlation between the score of Boileau and the total Constant score at the latest follow-up, but there was correlation between glenoid loosening and pain (p = 0.001). We found that total shoulder replacement had an excellent mid-term survivorship and clinical outcome. The surgical and cementing techniques were related to the decrease in radiolucent lines around the glenoid compared with earlier studies. One concern, however, was the fact that radiolucent lines increased over time and there was a rate of glenoid loosening of 9% after five years and 33% after nine years. This suggests that the design of the glenoid component, and the implantation and cementing techniques may need further improvement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic comparison of pegged and keeled glenoid components using modern cementing techniques: a prospective randomized study.

BACKGROUND Modern cementing techniques have improved glenoid fixation, reduced glenoid lucency seen with keeled components, and may eliminate differences attributable to glenoid design. The purpose of this study was to determine the effect of glenoid design on immediate and follow-up radiographic lucency of pegged and keeled glenoid components, using modern cementing techniques. MATERIAL AND ...

متن کامل

The radiographic evaluation of keeled and pegged glenoid component insertion.

BACKGROUND Radiolucent lines about the glenoid component of a total shoulder replacement are a common finding, even on initial postoperative radiographs. The achievement of complete osseous support of the component has been shown to decrease micromotion. We evaluated the ability of a group of experienced shoulder surgeons to achieve complete cementing and support in a series of patients managed...

متن کامل

Radiographic Evaluation of Glenoid Components and its Survivorship

Introduction: This study evaluated the survivorship of pegged versus keeled cemented, all-polyethylene glenoid components using modern cementing and glenoid preparation techniques. Survival of glenoid design was determined according to severity of radiolucencies on follow-up radiographs. Methods: Between April 22, 1999, and February 17, 2009, retrospective chart review was performed on 194 tota...

متن کامل

Mid- to long-term follow-up of total shoulder arthroplasty using a keeled glenoid in young adults with primary glenohumeral arthritis.

BACKGROUND The purpose of this study was to examine the mid- to long-term functional outcome and implant survival of total shoulder arthroplasty (TSA) in adults aged 55 years or younger with primary glenohumeral arthritis. The hypothesis was that TSA would lead to improvement in functional outcome but that implant survival would decline between 5 years and 10 years postoperatively. MATERIALS ...

متن کامل

A multicentre study of the long-term results of using a flat-back polyethylene glenoid component in shoulder replacement for primary osteoarthritis.

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2010