The power-velocity integral at the vena contracta: A new method for direct quantification of regurgitant volume flow.
نویسندگان
چکیده
BACKGROUND Noninvasive quantification of regurgitation is limited because Doppler measures velocity, not flow. Because backscattered Doppler power is proportional to sonified blood volume, power times velocity should be proportional to flow rate. Early studies, however, suggested that this held only for laminar flow, not for regurgitant jets, in which turbulence and fluid entrainment augment scatter. We therefore hypothesized that this Doppler power principle can be applied at the proximal vena contracta, where flow is laminar before entrainment, so that the power-times-velocity integral should vary linearly with flow rate and its time integral with stroke volume (SV). METHODS AND RESULTS This was tested in vitro with steady and pulsatile flow through 0.07- to 0.8-cm(2) orifices and in 36 hemodynamic stages in vivo, replacing the left atrium with a rigid chamber and column for direct visual recording of mitral regurgitant SV (MRSV). In 12 patients, MRSV was compared with MRI mitral inflow minus aortic outflow and in 11 patients with 3D echo left ventricular ejection volume-Doppler aortic forward SV. Vena contracta power in the narrow high-velocity spectrum from a broad measuring beam was calibrated against that from a narrow reference beam of known area. Calculated and actual flow rates and SV correlated well in vitro (r=0.99, 0.99; error=-1.6+/-2.5 mL/s, -2. 4+/-2.9 mL), in vivo (MRSV: r=0.98, error=0.04+/-0.87 mL), and in patients (MRSV: r=0.98, error=-2.8+/-4.5 mL). CONCLUSIONS The power-velocity integral at the vena contracta provides an accurate direct measurement of regurgitant flow, overcoming the limitations of existing Doppler techniques.
منابع مشابه
Assessment of Mitral Regurgitation Severity by Doppler Color Flow Mapping of the Vena Contracta in Dogs
BACKGROUND Although Doppler color flow mapping is widely used to assess the severity of mitral regurgitation (MR), a simple, accurate, and quantitative marker of MR by color flow mapping remains elusive. We hypothesized that vena contracta width by color flow mapping would accurately predict the severity of MR. METHODS AND RESULTS We studied 80 patients with MR. Vena contracta width was measu...
متن کاملComparison of vena contracta width by multiplane transesophageal echocardiography with quantitative Doppler assessment of mitral regurgitation.
Mitral regurgitation (MR) severity is routinely assessed by Doppler color flow mapping, which is subject to technical and hemodynamic variables. Vena contracta width may be less influenced by hemodynamic variables and has previously been shown to correlate with angiographic estimates of MR severity. This study was performed to compare mitral vena contracta width by multiplane transesophageal ec...
متن کاملQuantification of functional mitral regurgitation by real-time 3D echocardiography: comparison with 3D velocity-encoded cardiac magnetic resonance.
OBJECTIVES The aim of this study was to evaluate feasibility and accuracy of real-time 3-dimensional (3D) echocardiography for quantification of mitral regurgitation (MR), in a head-to-head comparison with velocity-encoded cardiac magnetic resonance (VE-CMR). BACKGROUND Accurate grading of MR severity is crucial for appropriate patient management but remains challenging. VE-CMR with 3D three-...
متن کاملMean Velocity and Static Pressure in a Sharp-edge Circular Nozzle Jet
An axisymmetric jet issued from a sharp edged circular convergent nozzle has been studied experimentally in the near field at Reynolds number 5.3x104 to search the saddle shape behavior of mean velocity and the role of mean static pressure in the jet flow. Due to the vena contracta effect the centerline mean velocity of the jet increases about 4.2% of its exit value and corresponding decrease ...
متن کاملQuantification of aortic regurgitation using high-pulse repetition frequency three-dimensional colour Doppler.
AIMS The aim of this study was to validate and assess the feasibility of a previously described method using multibeam high-pulse repetition frequency (HPRF) colour Doppler to quantify the vena contracta area (VCA) in aortic regurgitation (AR). METHODS Twenty-nine patients with mild to severe AR were studied. Regurgitant volume and fraction measured by magnetic resonance imaging (MRI) were us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 102 9 شماره
صفحات -
تاریخ انتشار 2000