BACKGROUND The endurance shuttle walking test (ESWT) has shown good responsiveness to interventions in patients with chronic obstructive pulmonary disease (COPD). However, the minimal important difference (MID) for this test remains unknown, therefore limiting its interpretability. METHODS Patients with COPD who completed two or more ESWTs following pulmonary rehabilitation (n=132; forced expiratory volume in 1 s (FEV1) 48 ± 22%) or bronchodilation (n=69; FEV1 50 ± 12%) rated their performance of the day in comparison with their previous performance on a 7-point scale ranging from -3 (large deterioration) to +3 (large improvement). The relationship between subjective perception of changes and objective changes in performance during the shuttle walk was evaluated. RESULTS Following pulmonary rehabilitation, the anchor-based approach did not allow a valid estimation of the MID in the ESWT performance to be obtained. After bronchodilation, patient ratings of change correlated significantly with the difference in walking distance (r=0.53, p<0.001) and endurance time (r=0.55, p<0.001). For the pharmacotherapy data, regression analysis indicated that a 65 s (95% CI 45 to 85) change in endurance time and a 95 m (95% CI 60 to 115) change in walking distance were associated with a 1-point change in the rating of change scale. These changes represented 13-15% of the baseline values. CONCLUSIONS A change in endurance shuttle walking performance of 45-85 s (or 60-115 m) after bronchodilation is likely to be perceived by patients. This MID value may be specific to the intervention from which it was derived.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CHRONIC OBSTRUCTIVE PULMONARY DISEASE Six-minute walking versus shuttle walking: responsiveness to bronchodilation in chronic obstructive pulmonary disease

Background: The responsiveness of the endurance shuttle walk to functional changes following bronchodilation has recently been reported. The current literature suggests that the 6 min walking test (6MWT) is less responsive to bronchodilation than the endurance shuttle walk. Aim: To compare bronchodilator-induced changes in exercise performance with the 6MWT and the endurance shuttle walk. Metho...

متن کامل

Six-minute walking versus shuttle walking: responsiveness to bronchodilation in chronic obstructive pulmonary disease.

BACKGROUND The responsiveness of the endurance shuttle walk to functional changes following bronchodilation has recently been reported. The current literature suggests that the 6 min walking test (6MWT) is less responsive to bronchodilation than the endurance shuttle walk. AIM To compare bronchodilator-induced changes in exercise performance with the 6MWT and the endurance shuttle walk. MET...

متن کامل

Relationship Between Core Stability Power and Endurance with Performance of Adolescence Athletes

Core stability (CS) is a popular term that has evolved into a fundamental concept the much rehabilitation, performance training and preventative programs. The purpose of this study is considering the relationship between CS power and endurance with performance of adolescence athletes. 12 male swimmers participated in the study. McGill Protocol, the core stability power, MBESTT and 30/60 sit-up ...

متن کامل

The endurance shuttle walk: a new field test for the assessment of endurance capacity in chronic obstructive pulmonary disease.

BACKGROUND The purpose of this study was to develop an externally controlled, constant paced field walking test to assess endurance capacity in patients with chronic obstructive pulmonary disease (COPD). There were four objectives: (1) to develop a protocol; (2) to compare treadmill and shuttle walk tests of endurance capacity; (3) to examine the repeatability of the endurance shuttle walk test...

متن کامل

Endurance shuttle walking test: responsiveness to salmeterol in COPD.

Few studies have shown that the endurance shuttle walking test (ESWT) is responsive to treatment in patients with chronic obstructive pulmonary disease (COPD). This exercise test needs to be further investigated because of its relevance for activity of daily living. The aim of the present study was to evaluate, in patients with COPD, the responsiveness of the ESWT in detecting improvement in wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 66 2  شماره 

صفحات  -

تاریخ انتشار 2011