Use of human fibrin glue (Tisseel) versus staples for mesh fixation in laparoscopic transabdominal preperitoneal hernioplasty (TISTA): a randomized controlled trial (NCT01641718)

نویسندگان

  • Sascha A Müller
  • Rene Warschkow
  • Ulrich Beutner
  • Cornelia Lüthi
  • Kristjan Ukegjini
  • Bruno M Schmied
  • Ignazio Tarantino
چکیده

BACKGROUND Inguinal hernia repair is one of the most common surgical procedures worldwide. This procedure is increasingly performed with endoscopic techniques (laparoscopy). Many surgeons prefer to cover the hernia gap with a mesh to prevent recurrence. The mesh must be fixed tightly, but without tension. During laparoscopic surgery, the mesh is generally fixed with staples or tissue glue. However, staples often cause pain at the staple sites, and they can cause scarring of the abdominal wall, which can lead to chronic pain. We designed a trial that aims to determine whether mesh fixation with glue might cause less postoperative pain than fixation with staples during a transabdominal preperitoneal patch plastic repair. METHODS/DESIGN The TISTA trial is a prospective, randomized, controlled, single-center trial with a two-by-two parallel design. All patients and outcome-assessors will be blinded to treatment allocations. For eligibility, patients must be male, ≥18 years old, and scheduled for laparoscopic repair of a primary inguinal hernia. One group comprises patients with a unilateral inguinal hernia that will be randomized to receive mesh fixation with either tissue glue or staples. The second group comprises patients with bilateral inguinal hernias. They will be randomized to receive mesh fixation with tissue glue either on the right or the left side and with staples on the other side. The primary endpoint will be pain under physical stress, measured at 24 h after surgery. Pain will be rated by the patient based on a numeric rating scale from 0 to 10, where 10 equals the worst pain imaginable. A total of 82 patients will be recruited (58 patients with unilateral inguinal hernias and 24 patients with bilateral hernias). This number is estimated to provide 90% power for detecting a pain reduction of one point on a numeric rating scale, with a standard deviation of one. DISCUSSION Patients with bilateral hernias will receive two meshes, one fixed with glue, and the other fixed with staples. This design will eliminate the inter-individual bias inherent in comparing pain measurements between two groups of patients. TRIAL REGISTRATION ClinicalTrials.gov: NCT01641718.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transabdominal Preperitoneal Herniorrhaphy using Laser-Assisted Tissue Soldering in a Porcine Model

BACKGROUND AND OBJECTIVES Collagen solder is capable of fixation of surgical meshes during laparoscopic herniorrhaphy without compromising tissue integration, increasing adhesions or inflammation. This pilot study describes development of instrumentation and techniques for transabdominal preperitoneal (TAPP) herniorrhaphy using laser-assisted soldering technology. METHODS Anesthetized 20-kg t...

متن کامل

Self-gripping mesh versus fibrin glue fixation in laparoscopic inguinal hernia repair: a randomized prospective clinical trial in young and elderly patients

Laparoscopic transabdominal preperitoneal inguinal hernia repair is a safe and effective technique. In this study we tested the hypothesis that self-gripping mesh used with the laparoscopic approach is comparable to polypropylene mesh in terms of perioperative complications, against a lower overall cost of the procedure. We carried out a prospective randomized trial comparing a group of 30 pati...

متن کامل

Biomechanical evaluation of three fixation modalities for preperitoneal inguinal hernia repair: a 24-hour postoperative study in pigs

PURPOSE Tacks and sutures ensure a strong fixation of meshes, but they can be associated with pain and discomfort. Less invasive methods are now available. Three fixation modalities were compared: the ProGrip™ laparoscopic self-fixating mesh; the fibrin glue Tisseel™ with Bard™ Soft Mesh; and the SorbaFix™ absorbable fixation system with Bard™ Soft Mesh. MATERIALS AND METHODS Meshes (6 cm ×6 ...

متن کامل

Tissue Glue in Laparoscopic Inguinal Hernia Repair: A Retrospective Comparative Analysis

During the last two decades, there have been two revolutions in inguinal hernia repair surgery. First, the introduction of tension-free hernia repair by Liechtenstein in 1989 and then the application of laparoscopic surgery to the treatment of inguinal hernia in the early 1990s. In this context, the choice of mesh fixation methods being an integral part of this procedure remains a topic of argu...

متن کامل

A comparison of post operative pain and hospital stay between Lichtenstein’s repair and Laparoscopic Transabdominal Preperitoneal (TAPP) repair of inguinal hernia: A randomized controlled trial

OBJECTIVE To compare the open Lichtenstein repair and laparoscopic mesh repair for direct inguinal hernias in terms of immediate post operative pain and length of hospital stay. METHODS This randomized control trial was conducted at Benazir Bhutto Hospital Rawalpindi from January 2009 to June 2010. All patients presenting in the surgical OPD with direct inguinal hernia, ASA I/II, were randoml...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014