Proof of concept non-invasive estimation of peripheral venous oxygen saturation
نویسندگان
چکیده
BACKGROUND Pulse oximeters continuously monitor arterial oxygen saturation. Continuous monitoring of venous oxygen saturation (SvO2) would enable real-time assessment of tissue oxygen extraction (O2E) and perfusion changes leading to improved diagnosis of clinical conditions, such as sepsis. METHODS This study presents the proof of concept of a novel pulse oximeter method that utilises the compliance difference between arteries and veins to induce artificial respiration-like modulations to the peripheral vasculature. These modulations make the venous blood pulsatile, which are then detected by a pulse oximeter sensor. The resulting photoplethysmograph (PPG) signals from the pulse oximeter are processed and analysed to develop a calibration model to estimate regional venous oxygen saturation (SpvO2), in parallel to arterial oxygen saturation estimation (SpaO2). A clinical study with healthy adult volunteers (n = 8) was conducted to assess peripheral SvO2 using this pulse oximeter method. A range of physiologically realistic SvO2 values were induced using arm lift and vascular occlusion tests. Gold standard, arterial and venous blood gas measurements were used as reference measurements. Modulation ratios related to arterial and venous systems were determined using a frequency domain analysis of the PPG signals. RESULTS A strong, linear correlation (r 2 = 0.95) was found between estimated venous modulation ratio (RVen) and measured SvO2, providing a calibration curve relating measured RVen to venous oxygen saturation. There is a significant difference in gradient between the SpvO2 estimation model (SpvO2 = 111 - 40.6*R) and the empirical SpaO2 estimation model (SpaO2 = 110 - 25*R), which yields the expected arterial-venous differences. Median venous and arterial oxygen saturation accuracies of paired measurements between pulse oximeter estimated and gold standard measurements were 0.29 and 0.65%, respectively, showing good accuracy of the pulse oximeter system. CONCLUSIONS The main outcome of this study is the proof of concept validation of a novel pulse oximeter sensor and calibration model to assess peripheral SvO2, and thus O2E, using the method used in this study. Further validation, improvement, and application of this model can aid in clinical diagnosis of microcirculation failures due to alterations in oxygen extraction.
منابع مشابه
Validity of Peripheral Capillary Oxygen Saturation and Normal Mixed Venous Oxygen Tension in Measurement of O2 Content
Background The change in venous oxygen saturation occurs earlier, and even its reduction is faster than arterial oxygen saturation. The aim of this study was to validate SvO2 and PvO2 for O2 content measurement in children hospitalized w...
متن کاملNon-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry
BACKGROUND To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO2-retinal) and venous (SvO2-retinal) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. METHODS Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and d...
متن کاملCMR-based blood oximetry via multi-parametric estimation using multiple T2 measurements
BACKGROUND Measurement of blood oxygen saturation (O2 saturation) is of great importance for evaluation of patients with many cardiovascular diseases, but currently there are no established non-invasive methods to measure blood O2 saturation in the heart. While T2-based CMR oximetry methods have been previously described, these approaches rely on technique-specific calibration factors that may ...
متن کاملNon-invasive estimation of venous admixture: validation of a new formula.
We have developed a computer program that estimates venous admixture (intra-pulmonary shunt) from four measurements: haemoglobin concentration, end-tidal carbon dioxide tension (PE'CO2), fractional inspired oxygen concentration (FIO2) and pulse oximetry (SpO2). The formula was tested on patients in an intensive therapy unit by using it to estimate shunt while it was measured simultaneously by a...
متن کاملThe Hemodynamic Effects of Drugs on Myocardial Oxygen Use
The circulatory responses to high equinalgesic doses of morphine are compared with those of pethidin. The decrease in mean arterial blood pressure in case of morphine was 28p.c., with a paralleled and identical decrease in total peripheral resistance and no negative inotropic effects. Pethidine decreased blood pressure 54p.c., as a result of peripheral vasodilation of 46p.c. and a sharp drop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2017