[Measurements and comparisons for data of small beams of linear accelerators].
نویسندگان
چکیده
BACKGROUND AND OBJECTIVE Accurate data acquisition is very important to establish a reliable dose calculation model of the treatment planning system for small radiation fields in intensity modulated radiation therapy (IMRT) and stereotactic radiotherapy (SRT). This study was to analyze and compare small-field measurements using different methods and ionization chambers. METHODS Three types of farmer chambers were used, with active volumes of 0.65 cc, and 0.13 cc, 0.01 cc, respectively. The beam data, including the total scatter factor (Scp), collimator scatter factor (Sc), tissue-maximum ratio (TMR), were acquired in a 30 cm x 30 cm x 30 cm3 water phantom under two linear accelerators. Measurements were performed at accelerating potentials of 4, 6, and 8 MV with the beam size ranging from 1 cm x 1 cm to 10 cm x 10 cm. The measurements were analyzed and compared. RESULTS For the beam size of >or=3 cm x 3 cm, the differences in Scp and Sc measurements of the 0.65 cc, 0.13 cc and 0.01 cc ion chambers were within 0.8%, while the differences were much greater for the beam size of less than 3 cm x 3 cm (the maximum difference reached 64%). Using 4, 6 and 8 MV X-rays, Sc measured by the 0.13 cc chamber with an elongated source-to-surface distance (SSD) (>150 cm) were 25.4%, 6.9%, 24.6%, and 1.4%, 1.4%, 2.2% greater than those measured by a standard SSD (100 cm) for 1 cm x 1 cm and 2 cm x 2 cm beams respectively; although there was no significant difference in Sc measurements for the beams of >or=2 cm x 2 cm using the elongated SSD of the 0.13 cc and the 0.01 cc ion chambers, Sc measured by the 0.13 cc ion chamber were 0.2%, 8.5%, 3.4% less than those measured by the 0.01 cc ion chamber for the 1 cm x 1 cm beam. For the 1 cm x 1 cm beam, the TMR of the depth deeper than 15 cm measured with the 0.01 cc ion chamber was about 4% different compared with that measured with the 0.13 cc ion chamber; for radiation fields of >or=2 cm x 2 cm, the differences of TMR between the 0.01 cc and 0.13 cc chambers were within 1%. For the radiation fields of >or=3 cm x 3 cm, the measured TMR values had a good consistency with the calculated values obtained from the percentage depth doses (PDDs) at the depth of 0 to 15 cm; but the two values were obviously different at the depths of deeper than 15 cm (>2%). CONCLUSIONS For the measurement of small fields, the choice of a suitable detector is important due to the lack of lateral electron equilibrium. Misuse of the detector may affect the accuracy of the measurements for small radiation fields. When the lateral electron equilibrium is not established, the size of the detector used to measure the absorbed dose on the central axis should be considerably smaller than the field size.
منابع مشابه
Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation
Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...
متن کاملThe effect of electronic disequilibrium on the received dose by lung in small fields with photon beams: Measurements and Monte Carlo study
Background: Prediction of the absorbed dose in irradiated volume plays an important role in the outcome of radiotherapy. Application of small fields for radiotherapy of thorax makes the dose calculation process inaccurate due to the existence of electronic disequilibrium and intrinsic deficiencies in dose calculation algorithms. To study the lung absorbed dose in radiotherapy with smal...
متن کاملEvaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields
Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...
متن کاملFree Vibration Analysis of Quintic Nonlinear Beams using Equivalent Linearization Method with a Weighted Averaging
In this paper, the equivalent linearization method with a weighted averaging proposed by Anh (2015) is applied to analyze the transverse vibration of quintic nonlinear Euler-Bernoulli beams subjected to axial loads. The proposed method does not require small parameter in the equation which is difficult to be found for nonlinear problems. The approximate solutions are harmonic oscillations, whic...
متن کاملCalculation the phantom scatter factor for the linear accelerators device
Introduction: In the last few decades, a lot of monte carlo codes have been introduced for medical applications. this is important because through simulation, we are fully independent of the spectral scattering factor that we are not able measure in real terms. The effect of the radiation energy, the dimension of the radiation field, the sensitive volume of the ion chamber on t...
متن کاملNew electrical device for field coincidence quality control test in linear accelerators
Testing of the coincidence of a linear accelerators X-ray field and the light field as a quality control test is often done in a subjective method, involving the manual marking of pieces of film and the visual inspection of the film after irradiation. The purpose of this study was to develop an objective method for performing this test, while also increasing the accuracy, precision and the spee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ai zheng = Aizheng = Chinese journal of cancer
دوره 28 3 شماره
صفحات -
تاریخ انتشار 2009